OSHA SearchOSHA records by employer

Dolan Builders, LLC: OSHA inspections and violations

Stowe, Vermont · Roofing Contractors · NAICS 238160

3inspections
7citation items
$2,300current penalties
Aug 11, 2016last inspection

Since 2011, OSHA inspectors have visited Dolan Builders, LLC in Vermont 3 times.

The most recent inspection opened on Aug 11, 2016, in Stowe.

In all, OSHA issued 7 citation items: 5 serious and 2 repeat.

The proposed penalties came to $10,700; today they stand at $2,300, 79% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. Dolan Builders, LLC averages $1,000 across 2 cited inspections.

Dolan Builders, LLC: OSHA citation items per year, 2011 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites Dolan Builders, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341688844 OPENED AUG 11, 2016Closed

Programmed other · Partial · Safety · 10 employees at the site · Closed Feb 27, 2017

745 S Main Street, Stowe, VT 05672 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$2,400$0Sep 1, 2016Final
Citation 1, item 1b
29 CFR 1926.451(g)(4)(xv) · Scaffolds, general requirements
Serious$0$0Sep 1, 2016Final
Citation 1, item 1c
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Sep 1, 2016Final
Citation 1, item 1d
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Sep 1, 2016Final
Citation 2, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Repeat$4,000$0Sep 1, 2016Final

Inspection 341499390 OPENED MAY 25, 2016Closed

Programmed other · Partial · Safety · 9 employees at the site · Closed Aug 24, 2016

1675 Us Route 2, Waterbury, VT 05676 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Repeat$4,000$2,000Jun 22, 2016Final

Inspection 314219221 OPENED JUN 28, 2011Closed

Unprogrammed other · Partial · Safety · 2 employees at the site · Closed Aug 4, 2011

Mtn Rd, Stowe, VT 05672 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$300$300Jul 26, 2011Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in Vermont

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.