OSHA SearchOSHA records by employer

Dougherty Electric, Inc.: OSHA inspections and violations

Philadelphia, Pennsylvania · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

11inspections
12citation items
$11,445current penalties
Sep 8, 2026last inspection

Dougherty Electric, Inc. has 11 OSHA inspections on record in Pennsylvania, the first in 2002.

OSHA's last visit started on Sep 8, 2026 as a planned inspection, in Philadelphia.

Across those inspections OSHA issued 12 citation items: 2 serious and 10 other-than-serious.

OSHA proposed $19,375 in penalties. After settlements and reviews the total is $11,445, down 41%.

Most often, OSHA cited 1926.403, electrical equipment on job sites (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Dougherty Electric, Inc. averages $2,825 over 3 cited inspections in that time.

Dougherty Electric, Inc. also files yearly injury logs with OSHA, summarized below.

Dougherty Electric, Inc.: OSHA citation items per year, 2002 to 2026
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

285employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Dougherty Electric, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 349156505 OPENED SEP 8, 2026Closed

Planned · Partial · Safety · 10 employees at the site · Closed Sep 30, 2026

1301 Chestnut Street, Philadelphia, PA 19107 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 348026204 OPENED FEB 6, 2025Closed

Planned · Partial · Safety · 29 employees at the site · Closed Apr 24, 2025

1701 Market St, Philadelphia, PA 19102 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345181820 OPENED MAR 2, 2021Closed

Planned · Partial · Safety · 16 employees at the site · Closed Sep 30, 2021

1520 Hamilton St, Philadelphia, PA 19130 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344011143 OPENED MAY 15, 2019Closed

Planned · Complete · Safety · 50 employees at the site · Closed May 16, 2019

1324 North Broad Street, Philadelphia, PA 19121 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341247591 OPENED FEB 11, 2016Closed

Referral · Partial · Safety · 20 employees at the site · Closed May 19, 2016

2400 Market St., Philadelphia, PA 19103 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Other-than-serious$2,400$2,400Mar 4, 2016Final
Citation 1, item 1b
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Other-than-serious$2,400$2,400Mar 4, 2016Final

Inspection 341100519 OPENED DEC 3, 2015Closed

Complaint · Records only · Health · 92 employees at the site · Closed Jun 8, 2016

45 W. Porter Street, Philadelphia, PA 19148 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.32(a)(3) · Yearly injury summary
Other-than-serious$700$700May 24, 2016Final

Inspection 341056265 OPENED NOV 13, 2015Closed

Planned · Complete · Safety · 7 employees at the site · Closed Dec 22, 2015

425 Sixth Avenue, Pittsburgh, PA 15222 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Other-than-serious$2,975$2,975Nov 30, 2015Final

Inspection 339041428 OPENED APR 19, 2013Closed

Unprogrammed other · Partial · Safety · 80 employees at the site · Closed Jul 10, 2013

3200 Chestnut St., Philadelphia, PA 19103 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(1)(ii) · Electrical equipment on job sites
Other-than-serious$3,000$750Jun 28, 2013Final
Citation 1, item 2
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Other-than-serious$4,200$750Jun 28, 2013Final
Citation 2, item 1
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$0$0Jun 28, 2013Final
3 older inspections

Inspection 339016859 OPENED APR 18, 2013Closed

Planned · Partial · Safety · 12 employees at the site · Closed Jul 17, 2013

1200 Arch Street, Philadelphia, PA 19107 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Other-than-serious$2,100$500Jun 26, 2013Final

Inspection 307015818 OPENED NOV 4, 2003Closed

Unprogrammed related · Partial · Safety · 2 employees at the site · Closed Apr 12, 2004

Victory Building, Philadelphia, PA 19104 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$900$570Dec 8, 2003Final
Citation 2, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Other-than-serious$0$0Dec 8, 2003Final

Inspection 305372385 OPENED OCT 31, 2002Closed

Unprogrammed other · Partial · Safety · 2 employees at the site · Closed Dec 15, 2002

Austin Manor Apartments, Philadelphia, PA 19111 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Serious$700$400Nov 13, 2002Final
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Nov 13, 2002Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2021, the Philadelphia site logged 5 recordable injuries or illnesses among about 90 workers: 5.8 per 100 full-time workers, against a median of 1.8 for its industry. Those cases cost 136 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Dougherty Electric, Inc.
Philadelphia · 2021
90 545.81.8

Included with any plan: 4 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1904.32 · Yearly injury summary

29 CFR 1904.32(a)(3)

(3) Certify the summary; and

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(ii)

(ii) One stairrail system along each unprotected side or edge.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.453 · Aerial lifts

Other electrical contractors and other wiring installation contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.