OSHA SearchOSHA records by employer

Duffy's Electric, LLC.: OSHA inspections and violations

Bangor, Maine · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

9inspections
16citation items
$9,569current penalties
Jun 30, 2022last inspection

OSHA has inspected Duffy's Electric, LLC. 9 times in Maine since 1997.

The latest one began on Jun 30, 2022 as part of a related case, in Cutler.

Those inspections ended with 16 citation items: 10 serious and 6 other-than-serious.

Penalties were first proposed at $19,163 and now stand at $9,569, 50% lower after settlements or reviews.

Job-site wiring comes up most often in these citations: 6 items under 1926.405.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Duffy's Electric, LLC. averages $4,144 (1 cited inspection).

Duffy's Electric, LLC.: OSHA citation items per year, 1997 to 2022
Citation items per year, by inspection date.

Maine · latest 90 days of OSHA records

31employers cited

Get notified the morning OSHA posts each new citation in Maine: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maine

Checking a subcontractor, a client or your own company? Watch Duffy's Electric, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346054026 OPENED JUN 30, 2022Closed

Unprogrammed related · Partial · Safety · 15 employees at the site · Closed Oct 5, 2022

Building 300, Cutler, ME 04626 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.652(a)(1) · Trench protection
Serious$4,144$4,144Sep 13, 2022Final
Citation 1, item 1b
29 CFR 1926.651(k)(1) · Excavations
Serious$4,144$0Sep 13, 2022Final
Citation 2, item 1
29 CFR 1904.40(a) · Giving injury records to OSHA
Other-than-serious$0$0Sep 13, 2022Final

Inspection 339436610 OPENED OCT 21, 2013Closed

Planned · Complete · Safety · 2 employees at the site · Closed Nov 19, 2013

Rangeley Road, Orono, ME 04469 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 1926.405(a)(2)(ii)(j) · Job-site wiring
Other-than-serious$0$0Oct 31, 2013Final
Citation 2, item 2
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Other-than-serious$2,000$0Oct 31, 2013Final

Inspection 337631410 OPENED NOV 27, 2012Closed

Unprogrammed other · Complete · Safety · 1 employee at the site · Closed Jan 9, 2013

498 Maine Avenue, Bangor, ME 04401 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$1,600$1,000Dec 19, 2012Final

Inspection 315195651 OPENED MAR 10, 2011Closed

Unprogrammed related · Complete · Safety · 1 employee at the site · Closed Apr 28, 2011

40 Springer Drive, Bangor, ME 04401 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$3,000$2,100Apr 5, 2011Closed
Citation 2, item 1
29 CFR 1926.403(h) · Electrical equipment on job sites
Other-than-serious$0$0Apr 5, 2011Closed

Inspection 314540212 OPENED JUN 10, 2010Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed Jun 30, 2010

60 Fairgrounds Mkt Pl, Skowhegan, ME 04976 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Other-than-serious$600$0Jun 21, 2010Closed

Inspection 312516164 OPENED AUG 27, 2008Closed

Unprogrammed other · Partial · Safety · 3 employees at the site · Closed Nov 21, 2008

1133 Union Street, Bangor, ME 04401 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Other-than-serious$1,000$0Oct 29, 2008Closed
Citation 1, item 3
29 CFR 1926.405(a)(2)(iie) · Job-site wiring
Serious$800$600Oct 29, 2008Closed
Citation 1, item 4
29 CFR 1926.405(a)(2)(iif) · Job-site wiring
Serious$600$600Oct 29, 2008Closed
Citation 1, item 5
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$600$450Oct 29, 2008Closed

Inspection 112570262 OPENED APR 16, 2003Closed

Unprogrammed other · Complete · Safety · 10 employees at the site · Closed May 19, 2003

705 Wilson Street, Brewer, ME 04412 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 303783559 OPENED FEB 7, 2001Closed

Planned · Partial · Safety · 7 employees at the site · Closed Mar 16, 2001

Broadway Shop 'n Save, Bangor, ME 04401 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$225$225Feb 14, 2001Closed
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$225$225Feb 14, 2001Closed
Citation 1, item 3
29 CFR 1926.454(c) · Scaffold training
Serious$225$225Feb 14, 2001Closed
1 older inspection

Inspection 300297157 OPENED OCT 27, 1997Closed

Unprogrammed related · Partial · Health · 6 employees at the site · Closed Oct 28, 1997

633 Stillwater Avenue, Bangor, ME 04401 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.40 · Giving injury records to OSHA

29 CFR 1904.40(a)

(a) Basic requirement. When an authorized government representative asks for the records you keep under part 1904, you must provide copies of the records within four (4) business hours.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(ii)

(ii) One stairrail system along each unprotected side or edge.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(13)

(13) The top or top step of a stepladder shall not be used as a step.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

Other electrical contractors and other wiring installation contractors employers in Maine

Alert subscribers get notified of each newly cited employer in Maine the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.