OSHA SearchOSHA records by employer

Duran Masonry: OSHA inspections and violations

Austin, Texas · Masonry Contractors · NAICS 238140

4inspections
17citation items
$10,545current penalties
Nov 15, 2022last inspection

Duran Masonry has 4 OSHA inspections on record in Texas, the first in 1991.

OSHA's last visit started on Nov 15, 2022 as a planned inspection, in Farmers Branch.

Across those inspections OSHA issued 17 citation items: 15 serious and 2 other-than-serious.

OSHA proposed $11,895 in penalties. After settlements and reviews the total is $10,545, down 11%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (11 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Duran Masonry averages $9,945 over 1 cited inspection in that time.

Duran Masonry: OSHA citation items per year, 1991 to 2022
Citation items per year, by inspection date.

Want to know if OSHA cites Duran Masonry again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346350861 OPENED NOV 15, 2022Closed

Planned · Partial · Safety · 5 employees at the site · Closed Feb 1, 2023

12937 Coutur Dr., Farmers Branch, TX 75234 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$2,486$2,486Dec 15, 2022Final
Citation 1, item 2a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,108$3,108Dec 15, 2022Final
Citation 1, item 2b
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0Dec 15, 2022Final
Citation 1, item 3a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,351$4,351Dec 15, 2022Final
Citation 1, item 3b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Dec 15, 2022Final

Inspection 123551749 OPENED JUN 21, 1994Closed

Planned · Complete · Safety · 3 employees at the site · Closed Aug 22, 1994

6804 N Capital Of Texas Highway, Austin, TX 78731 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 110376134 OPENED OCT 16, 1991Closed

Monitoring · Partial · Safety · 10 employees at the site · Closed Oct 16, 1991

5811 Mesa Dr, Austin, TX 78731 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 119507895 OPENED AUG 28, 1991Closed

Planned · Complete · Safety · 4 employees at the site · Closed Apr 8, 1993

5811 Mesa Dr, Austin, TX 78731 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Serious$450$150Oct 10, 1991Closed
Citation 1, item 2
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$450$150Oct 10, 1991Closed
Citation 1, item 3a
29 CFR 1926.451(a)(3) · Scaffolds, general requirements
Serious$600$150Oct 10, 1991Closed
Citation 1, item 3b
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$0$0Oct 10, 1991Closed
Citation 1, item 3c
29 CFR 1926.451(d)(3) · Scaffolds, general requirements
Serious$0$0Oct 10, 1991Closed
Citation 1, item 3d
29 CFR 1926.451(d)(5) · Scaffolds, general requirements
Serious$0$0Oct 10, 1991Closed
Citation 1, item 4a
29 CFR 1926.451(a)(8) · Scaffolds, general requirements
Serious$450$150Oct 10, 1991Closed
Citation 1, item 4b
29 CFR 1926.451(a)(10) · Scaffolds, general requirements
Serious$0$0Oct 10, 1991Closed
Citation 1, item 4c
29 CFR 1926.451(a)(14) · Scaffolds, general requirements
Serious$0$0Oct 10, 1991Closed
Citation 1, item 4d
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$0$0Oct 10, 1991Closed
Citation 2, item 1
29 CFR 1926.20(b)(1) · Construction safety programs
Other-than-serious$0$0Oct 10, 1991Closed
Citation 2, item 2
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$0$0Oct 10, 1991Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(1)

(b) Accident prevention responsibilities. (1) It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.59 · Hazard communication

Other masonry contractors employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.