OSHA SearchOSHA records by employer

Dziekan Heating and Airconditioning, Inc.: OSHA inspections and violations

Altoona, Wisconsin · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

1inspections
3citation items
$2,640current penalties
Mar 3, 2015last inspection

Dziekan Heating and Airconditioning, Inc. has one OSHA inspection on record in Wisconsin.

OSHA opened it on Mar 3, 2015 as a planned inspection, in Altoona.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $4,400 in penalties. After settlements and reviews the total is $2,640, down 40%.

Most often, OSHA cited 1926.1052, stairways in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Dziekan Heating and Airconditioning, Inc. averages $2,640 over 1 cited inspection in that time.

Dziekan Heating and Airconditioning, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

216employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Dziekan Heating and Airconditioning, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340443506 OPENED MAR 3, 2015Closed

Planned · Complete · Safety · 5 employees at the site · Closed Apr 29, 2015

2455 Sawgrass Place, Altoona, WI 54720 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$2,000$1,200Mar 31, 2015Final
Citation 1, item 2a
29 CFR 1926.1052(b)(3) · Stairways in construction
Serious$2,400$1,440Mar 31, 2015Final
Citation 1, item 2b
29 CFR 1926.1052(c)(1)(i) · Stairways in construction
Serious$0$0Mar 31, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(b)(3)

(3) Treads for temporary service shall be made of wood or other solid material, and shall be installed the full width and depth of the stair.

29 CFR 1926.1052(c)(1)(i)

(i) At least one handrail; and

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(4)(ii)

(ii) Each employee on a walking/working surface shall be protected from tripping in or stepping into or through holes (including skylights) by covers.

Other plumbing, heating, and air-conditioning contractors employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.