OSHA SearchOSHA records by employer

E.L. Masonry, LLC.: OSHA inspections and violations

Manheim, Pennsylvania · Masonry Contractors · NAICS 238140

9inspections
20citation items
$17,058current penalties
Jun 1, 2023last inspection

E.L. Masonry, LLC. has 9 OSHA inspections on record in Pennsylvania, the first in 1998.

OSHA's last visit started on Jun 1, 2023, in Mount Wolf.

Across those inspections OSHA issued 20 citation items: 15 serious and 5 other-than-serious.

OSHA proposed $21,338 in penalties. After settlements and reviews the total is $17,058, down 20%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. E.L. Masonry, LLC. averages $2,391 over 3 cited inspections in that time.

E.L. Masonry, LLC.: OSHA citation items per year, 1998 to 2023
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

287employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch E.L. Masonry, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346742604 OPENED JUN 1, 2023Closed

Unprogrammed other · Partial · Safety · 9 employees at the site · Closed Dec 4, 2023

13 Maple Street, Mount Wolf, PA 17347 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$3,349$3,000Sep 22, 2023Final
Citation 1, item 1b
29 CFR 1910.1200(g)(9) · Hazard communication
Other-than-serious$0$0Sep 22, 2023Final

Inspection 345194658 OPENED MAR 11, 2021Closed

Referral · Partial · Safety · 3 employees at the site · Closed Aug 30, 2024

4000 Woodhaven Road, Philadelphia, PA 19154 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$2,926$2,926Sep 10, 2021Final
Citation 1, item 1b
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$0$0Sep 10, 2021Final

Inspection 343553335 OPENED OCT 23, 2018Closed

Unprogrammed related · Partial · Safety · 9 employees at the site · Closed Dec 14, 2018

20 Wilderness Trail, Hamburg, PA 19526 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,663$1,247Nov 16, 2018Final

Inspection 339659583 OPENED MAR 31, 2014Closed

Planned · Complete · Safety · 8 employees at the site · Closed May 7, 2014

1871 Santa Barbara Drive, Lancaster, PA 17601 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,000$1,500Apr 11, 2014Final

Inspection 314239930 OPENED JUN 3, 2010Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed Aug 2, 2010

14,16,18, South Hill Street, Stewartstown, PA 17363 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(15) · Fall protection in construction
Serious$1,500$1,125Jun 29, 2010Closed

Inspection 311275382 OPENED MAR 6, 2009Closed

Planned · Partial · Safety · 7 employees at the site · Closed May 27, 2009

1850 Airport Center Drive, Allentown, PA 18109 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(14) · Scaffolds, general requirements
Serious$1,500$1,500Mar 23, 2009Closed
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Mar 23, 2009Closed
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$1,500Mar 23, 2009Closed

Inspection 112899307 OPENED AUG 19, 2003Closed

Planned · Complete · Safety · 5 employees at the site · Closed Nov 5, 2003

2427 Craley Road, Wrightsville, PA 17368 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$975Sep 5, 2003Closed
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,500$975Sep 5, 2003Closed
Citation 1, item 3a
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$1,500$975Sep 5, 2003Closed
Citation 1, item 3b
29 CFR 1926.1053(b)(8) · Ladders in construction
Serious$0$0Sep 5, 2003Closed
Citation 1, item 3c
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$0$0Sep 5, 2003Closed
Citation 1, item 4
29 CFR 1926.250(a)(1) · General requirements for storage
Serious$600$390Sep 5, 2003Closed
Citation 2, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Other-than-serious$300$195Sep 5, 2003Closed

Inspection 116212911 OPENED MAR 24, 2000Closed

Planned · Complete · Safety · 3 employees at the site · Closed May 11, 2000

544 North Penryn Road, Manheim, PA 17545 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Other-than-serious$0$0Apr 28, 2000Closed
Citation 1, item 2
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Other-than-serious$0$0Apr 28, 2000Closed
1 older inspection

Inspection 116196361 OPENED MAY 26, 1998Closed

Unprogrammed related · Partial · Health · 8 employees at the site · Closed Jul 20, 1998

147 Doe Run Road, Manheim, PA 17545 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,500$750Jun 4, 1998Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(g)(9)

(9) Where employees must travel between workplaces during a workshift, i.e., their work is carried out at more than one geographical location, the safety data sheets may be kept at the primary workplace facility. In this situation, the employer shall ensure that employees can immediately obtain the required information in an emergency.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.250 · General requirements for storage

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other masonry contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.