OSHA SearchOSHA records by employer

E.T. Cornice Inc.: OSHA inspections and violations

New Caney, Texas · Finish Carpentry Contractors · NAICS 238350

1inspections
2citation items
$1,865current penalties
May 12, 2022last inspection

E.T. Cornice Inc. has one OSHA inspection on record in Texas.

OSHA opened it on May 12, 2022 as a planned inspection, in New Caney.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $3,108 in penalties. After settlements and reviews the total is $1,865, down 40%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. E.T. Cornice Inc. averages $1,865 over 1 cited inspection in that time.

E.T. Cornice Inc.: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch E.T. Cornice Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345954127 OPENED MAY 12, 2022Closed

Planned · Partial · Safety · 2 employees at the site · Closed Jul 7, 2022

23558 Marble Pass Trace, New Caney, TX 77357 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$3,108$1,865Jun 23, 2022Final
Citation 1, item 1b
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$0$0Jun 23, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(j)(2)

(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.