OSHA SearchOSHA records by employer

East Coast Metal Decks, Inc.: OSHA inspections and violations

Bushnell, Florida · Structural Steel and Precast Concrete Contractors · NAICS 238120

9inspections
22citation items
$18,070current penalties
Jun 26, 2015last inspection

Since 1987, OSHA inspectors have visited East Coast Metal Decks, Inc. in Florida 9 times.

The most recent inspection opened on Jun 26, 2015 as a planned inspection, in Royal Palm Beach.

In all, OSHA issued 22 citation items: 19 serious and 3 other-than-serious.

The proposed penalties came to $28,600; today they stand at $18,070, 37% less.

The rule cited most here is 1926.501 (fall protection in construction), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. East Coast Metal Decks, Inc. averages $3,500 across 1 cited inspection.

3 inspections on this page followed a fatal incident.

East Coast Metal Decks, Inc.: OSHA citation items per year, 1987 to 2015
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

315employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch East Coast Metal Decks, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340747492 OPENED JUN 26, 2015Closed

Planned · Partial · Safety · 3 employees at the site · Closed Jan 18, 2017

394 South State Road 7, Royal Palm Beach, FL 33411 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,500$3,500Jul 17, 2015Final

Inspection 314706334 OPENED JUN 20, 2010Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jun 15, 2016

209 N. Florida St., Bushnell, FL 33513 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$3,000$1,500Jul 23, 2010Closed
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$3,000$1,500Jul 23, 2010Closed
Citation 1, item 3
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,000$1,500Jul 23, 2010Closed

Inspection 311082481 OPENED JUN 15, 2007Closed

Planned · Complete · Safety · 10 employees at the site · Closed Oct 10, 2007

161 State Road 7, Royal Palm Beach, FL 33411 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$1,575$1,000Sep 19, 2007Closed
Citation 1, item 2
29 CFR 1926.602(c)(1)(viiia) · Earthmovers and forklifts in construction
Serious$3,000$2,000Sep 19, 2007Closed

Inspection 310208335 OPENED JUL 19, 2006Closed

Planned · Complete · Safety · 8 employees at the site · Closed Sep 11, 2006

620 Ne 22 Terrace, Homestead, FL 33033 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$375$375Aug 9, 2006Closed

Inspection 305989428 OPENED NOV 14, 2002Closed

Planned · Complete · Safety · 5 employees at the site · Closed Jul 6, 2004

209 N. Florida St., Bushnell, FL 33513 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$450$450Feb 25, 2003Closed
Citation 1, item 1b
29 CFR 1926.452(w)(1) · Rules for each type of scaffold
Serious$0$0Feb 25, 2003Closed
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$1,500Feb 25, 2003Closed
Citation 1, item 3a
29 CFR 1926.1052(a)(3) · Stairways in construction
Serious$450$450Feb 25, 2003Closed
Citation 1, item 3b
29 CFR 1926.1052(b)(1) · Stairways in construction
Serious$0$0Feb 25, 2003Closed
Citation 1, item 3c
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$0$0Feb 25, 2003Closed
Citation 1, item 3d
29 CFR 1926.26 · Illumination
Serious$0$0Feb 25, 2003Closed
Citation 2, item 1
29 CFR 1926.20(b)(1) · Construction safety programs
Other-than-serious$0$0Feb 25, 2003Closed
Citation 3, item 1
29 CFR 1903.19(c)(1) · Proving cited hazards were fixed
Other-than-serious$300$300May 28, 2003Closed

Inspection 301882122 OPENED MAR 2, 1999Closed

Accident · Complete · Safety · 4 employees at the site · Closed Jul 8, 1999

1105 Arvida Parkway, Weston, FL 33326 · OSHA's record · Phone and website on Google Maps

Incident on Feb 27, 1999 (fatal): Employee killed in fall from bar joists

Employee #1 was laying down metal decking over the bar joists when he fell onto the concrete floor. He died of head injuries sustained in the accident.

No citations from this inspection.

Inspection 300490034 OPENED OCT 2, 1996Closed

Accident · Complete · Safety · 30 employees at the site · Closed Jul 11, 1997

9850 Nw 17th St, Miami, FL 33142 · OSHA's record · Phone and website on Google Maps

Incident on Oct 2, 1996 (fatal): Employee killed in fall from roof

At about 10:20 a.m. on October 2 1996, Employee #1 was laying steel deck pans on the roof of a building. He was kicking a deck pan into place when he slipped an d fell to the ground. Employee #1 was killed. Although he was working at the lea ding edge of the deck, Employee #1 was not wearing fall protection. There was no controlled access zone, safety nets, or safety monitor in place.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$1,750$300Feb 28, 1997Closed
Citation 1, item 2
29 CFR 1926.21(b)(2) · Construction safety training
Serious$2,500$570Feb 28, 1997Closed
Citation 1, item 3
29 CFR 1926.105(a) · Safety nets
Serious$2,500$2,500Feb 28, 1997Closed

Inspection 106104706 OPENED MAY 11, 1988Closed

Accident · Complete · Safety · 1 employee at the site · Closed Sep 26, 1988

2400 N. Federal Hwy., Fort Lauderdale, FL 33301 · OSHA's record · Phone and website on Google Maps

Incident on May 11, 1988 (fatal): Employee killed when crushed by falling concrete panel

Employee #1 was assigned to weld together concrete panels on a tilt slab-type co nstruction. He had been employed for one month and this was his first day perfor ming this task. At approximately 3:00 p.m. the expansion bolts (quik bolts) hold ing the stiff leg to a previously set panel pulled out. The panel, which was sha ped like an inverted L, was supported by braces and the stiff leg and began to f all. Employee #1 ran under the falling panel, which weighed approximately 12 ton s, and was crushed to death.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$420$300Aug 29, 1988Closed
1 older inspection

Inspection 101204535 OPENED APR 7, 1987Closed

Referral · Complete · Safety · 6 employees at the site · Closed May 29, 1987

10 Fairway Dr., Deerfield Beach, FL 33441 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.28(a) · Personal protective equipment
Serious$640$325May 6, 1987Closed
Citation 1, item 2
29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart
Other-than-serious$640$0May 6, 1987Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(c)(1)

(c) Abatement certification. (1) Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.105 · Safety nets

29 CFR 1926.105(a)

(a) Safety nets shall be provided when workplaces are more than 25 feet above the ground or water surface, or other surfaces where the use of ladders, scaffolds, catch platforms, temporary floors, safety lines, or safety belts is impractical.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.21 · Construction safety training

29 CFR 1926.26 · Illumination

29 CFR 1926.28 · Personal protective equipment

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.602 · Earthmovers and forklifts in construction

29 CFR 1926.95 · Criteria for personal protective equipment

Other structural steel and precast concrete contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.