OSHA SearchOSHA records by employer

East West Seafood's, LLC: OSHA inspections and violations

Seattle, Washington · Ship Building and Repairing · NAICS 336611

2inspections
18citation items
$94,185current penalties
Feb 15, 2018last inspection

East West Seafood's, LLC has 2 OSHA inspections on record in Washington, the first in 2018.

OSHA's last visit started on Feb 15, 2018 on a referral, in Seattle.

Across those inspections OSHA issued 18 citation items: 14 serious, 3 repeat and 1 other-than-serious.

OSHA proposed $94,185 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.134, respiratory protection (6 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. East West Seafood's, LLC averages $47,092 over 2 cited inspections in that time.

East West Seafood's, LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Washington · latest 90 days of OSHA records

992employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Washington: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Washington

Checking a subcontractor, a client or your own company? Watch East West Seafood's, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342956646 OPENED FEB 15, 2018Closed

Referral · Complete · Health · 6 employees at the site · Closed Aug 20, 2024

F/v Pacific Producer 7001 Seaview Ave. N.w., Seattle, WA 98117 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$7,114$7,114Apr 24, 2018Final
Citation 1, item 1b
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$0$0Apr 24, 2018Final
Citation 1, item 2
29 CFR 1910.120(q)(6)(iii) · Hazardous waste operations and emergency response
Serious$9,959$9,959Apr 24, 2018Final
Citation 1, item 3a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$9,959$9,959Apr 24, 2018Final
Citation 1, item 3b
29 CFR 1910.134(k)(1)(iii) · Respiratory protection
Serious$0$0Apr 24, 2018Final
Citation 1, item 3c
29 CFR 1910.134(h)(3)(i)(b) · Respiratory protection
Serious$0$0Apr 24, 2018Final
Citation 1, item 3d
29 CFR 1910.134(h)(3)(iii) · Respiratory protection
Serious$0$0Apr 24, 2018Final
Citation 1, item 3e
29 CFR 1910.134(h)(3)(iv)(a) · Respiratory protection
Serious$0$0Apr 24, 2018Final
Citation 1, item 3f
29 CFR 1910.134(h)(3)(iv)(b) · Respiratory protection
Serious$0$0Apr 24, 2018Final
Citation 1, item 4a
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$5,691$5,691Apr 24, 2018Final
Citation 1, item 4b
29 CFR 1910.1200(h)(3)(iii) · Hazard communication
Serious$0$0Apr 24, 2018Final
Citation 1, item 5
OSH Act Section 5(a)(1) · General Duty Clause
Serious$9,959$9,959Apr 24, 2018Final
Citation 2, item 1
29 CFR 1910.1200(e)(1) · Hazard communication
Repeat$14,228$14,228Apr 24, 2018Final

Inspection 342956661 OPENED FEB 15, 2018Closed

Referral · Complete · Safety · 5 employees at the site · Closed Dec 2, 2025

M/v Pacific Producer 7001 Seaview Ave. N.w., Seattle, WA 98117 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1915.73(e) · Guarding of deck openings and edges
Serious$7,114$7,114Apr 24, 2018Final
Citation 1, item 2
29 CFR 1915.74(a)(1) · Access to vessels
Serious$9,959$9,959Apr 24, 2018Final
Citation 2, item 1
29 CFR 1910.101(b) · Compressed gases (general requirements)
Repeat$284$284Apr 24, 2018Final
Citation 2, item 2
29 CFR 1915.89(d)(1) · Control of hazardous energy (lockout/tags-plus)
Repeat$19,918$19,918Apr 24, 2018Final
Citation 3, item 1
29 CFR 1915.502(a) · Fire safety plan
Other-than-serious$0$0Apr 24, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.120 · Hazardous waste operations and emergency response

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1915.502 · Fire safety plan

29 CFR 1915.73 · Guarding of deck openings and edges

29 CFR 1915.74 · Access to vessels

29 CFR 1915.89 · Control of hazardous energy (lockout/tags-plus)

OSH Act Section 5 · General Duty Clause

Other ship building and repairing employers in Washington

Alert subscribers get notified of each newly cited employer in Washington the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.