OSHA SearchOSHA records by employer

Easter Creek Construction, Inc.: OSHA inspections and violations

Mccall, Idaho · Site Preparation Contractors · NAICS 238910

4inspections
23citation items
$6,150current penalties
Mar 1, 2017last inspection

OSHA has inspected Easter Creek Construction, Inc. 4 times in Idaho since 2000.

The latest one began on Mar 1, 2017 after a complaint, in Mccall.

Those inspections ended with 23 citation items: 23 serious.

Penalties were first proposed at $10,367 and now stand at $6,150, 41% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 4 items under 1910.134.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Easter Creek Construction, Inc. averages $4,500 (1 cited inspection).

Easter Creek Construction, Inc.: OSHA citation items per year, 2000 to 2017
Citation items per year, by inspection date.

Idaho · latest 90 days of OSHA records

61employers cited

Get notified the morning OSHA posts each new citation in Idaho: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Idaho

Checking a subcontractor, a client or your own company? Watch Easter Creek Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342142080 OPENED MAR 1, 2017Closed

Complaint · Partial · Safety · 10 employees at the site · Closed Oct 11, 2017

132 E Lakestreet, Mccall, ID 83638 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.302(a)(2) · Power-operated hand tools
Serious$2,897$1,500Apr 11, 2017Final
Citation 1, item 2a Serious$5,070$3,000Apr 11, 2017Final
Citation 1, item 2b
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$0$0Apr 11, 2017Final
Citation 1, item 2c
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Apr 11, 2017Final

Inspection 309966596 OPENED DEC 20, 2006Closed

Referral · Complete · Safety · 4 employees at the site · Closed Feb 28, 2007

611 3rd St., Mccall, ID 83638 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.651(k)(1) · Excavations
Serious$1,500$750Feb 8, 2007Closed
Citation 1, item 1b
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Feb 8, 2007Closed

Inspection 302583497 OPENED JAN 14, 2000Closed

Complaint · Partial · Safety · 1 employee at the site · Closed Mar 10, 2000

192 Industrial Loop, Mccall, ID 83638 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(f)(4) · Spray painting and finishing
Serious$450$450Jan 27, 2000Closed
Citation 1, item 1b
29 CFR 1910.107(g)(3) · Spray painting and finishing
Serious$0$0Jan 27, 2000Closed
Citation 1, item 1c
29 CFR 1910.107(g)(7) · Spray painting and finishing
Serious$0$0Jan 27, 2000Closed
Citation 1, item 1d
29 CFR 1910.125(e)(4)(i) · Additional requirements for dipping and coating operations that use flammable liquids or liquids with flashpoints greater than 199.4 °F (93 °C)
Serious$0$0Jan 27, 2000Closed
Citation 1, item 1e
29 CFR 1910.125(e)(5) · Additional requirements for dipping and coating operations that use flammable liquids or liquids with flashpoints greater than 199.4 °F (93 °C)
Serious$0$0Jan 27, 2000Closed
Citation 1, item 1f
29 CFR 1910.125(f)(2)(i) · Additional requirements for dipping and coating operations that use flammable liquids or liquids with flashpoints greater than 199.4 °F (93 °C)
Serious$0$0Jan 27, 2000Closed
Citation 1, item 1g
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Serious$0$0Jan 27, 2000Closed
Citation 1, item 1h
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Serious$0$0Jan 27, 2000Closed
Citation 1, item 1i
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Serious$0$0Jan 27, 2000Closed
Citation 1, item 1j
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$0$0Jan 27, 2000Closed
Citation 1, item 1k
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$0$0Jan 27, 2000Closed

Inspection 302583505 OPENED JAN 14, 2000Closed

Complaint · Partial · Health · 1 employee at the site · Closed Mar 10, 2000

192 Industrial Loop, Mccall, ID 83638 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$450$450Jan 27, 2000Closed
Citation 1, item 1b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Jan 27, 2000Closed
Citation 1, item 1c
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Jan 27, 2000Closed
Citation 1, item 1d
29 CFR 1910.134(h)(1) · Respiratory protection
Serious$0$0Jan 27, 2000Closed
Citation 1, item 1e
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$0$0Jan 27, 2000Closed
Citation 1, item 1f
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$0$0Jan 27, 2000Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(f)(4)

(4) Portable extinguishers. An adequate supply of suitable portable fire extinguishers shall be installed near all spraying areas.

29 CFR 1910.107(g)(3)

(3) Residue disposal. Residue scrapings and debris contaminated with residue shall be immediately removed from the premises and properly disposed of. Approved metal waste cans shall be provided wherever rags or waste are impregnated with finishing material and all such rags or waste deposited therein immediately after use. The contents of waste cans shall be properly disposed of at least once daily or at the end of each shift.

29 CFR 1910.107(g)(7)

(7) “No Smoking” signs. “No smoking” signs in large letters on contrasting color background shall be conspicuously posted at all spraying areas and paint storage rooms.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.125 · Additional requirements for dipping and coating operations that use flammable liquids or liquids with flashpoints greater than 199.4 °F (93 °C)

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1926.302 · Power-operated hand tools

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection