OSHA SearchOSHA records by employer

Eco D16 Joint Venture LLC: OSHA inspections and violations

San Juan, Puerto Rico · Commercial and Institutional Building Construction · NAICS 236220

1inspections
5citation items
$13,941current penalties
Nov 25, 2024last inspection

OSHA has inspected Eco D16 Joint Venture LLC once in Puerto Rico.

The inspection began on Nov 25, 2024 as a planned inspection, in San Juan; the case is still open.

That inspection ended with 5 citation items: 5 serious.

Penalties were first proposed at $13,941 and still stand at $13,941.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Eco D16 Joint Venture LLC averages $13,941 (1 cited inspection).

Eco D16 Joint Venture LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Puerto Rico · latest 90 days of OSHA records

109employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in Puerto Rico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Puerto Rico

Checking a subcontractor, a client or your own company? Watch Eco D16 Joint Venture LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347900961 OPENED NOV 25, 2024Open

Planned · Complete · Safety · 27 employees at the site · Open

Carr Pr-21 Km 2.9 Lote B, Bo. Monacillos, San Juan, PR 00926 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Serious$2,083$2,083Apr 10, 2025Contested
Citation 1, item 2
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$3,400$3,400Apr 10, 2025Contested
Citation 1, item 3
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$2,975$2,975Apr 10, 2025Contested
Citation 1, item 4
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$2,083$2,083Apr 10, 2025Contested
Citation 1, item 5
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$3,400$3,400Apr 10, 2025Contested

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other commercial and institutional building construction employers in Puerto Rico

Alert subscribers get notified of each newly cited employer in Puerto Rico the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.