OSHA SearchOSHA records by employer

Edc, Inc.: OSHA inspections and violations

Kernersville, North Carolina · Printed Circuit Assembly (Electronic Assembly) Manufacturing · NAICS 334418

7inspections
39citation items
$6,500current penalties
Jul 15, 2026last inspection

Since 1992, OSHA inspectors have visited Edc, Inc. in North Carolina 7 times.

The most recent inspection opened on Jul 15, 2026 as a planned inspection, in Kernersville.

In all, OSHA issued 39 citation items: 19 serious and 20 other-than-serious.

The proposed penalties came to $10,375; today they stand at $6,500, 37% less.

The rule cited most here is 1910.1200 (hazard communication), 8 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Edc, Inc. averages $0 across 1 cited inspection.

Edc, Inc.: OSHA citation items per year, 1992 to 2026
Citation items per year, by inspection date.

Want to know if OSHA cites Edc, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 349053439 OPENED JUL 15, 2026Closed

Planned · Complete · Health · 35 employees at the site · Closed Oct 23, 2026

950 Old Winston Road, Kernersville, NC 27284 · Printed Circuit Assembly (Electronic Assembly) Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Sep 1, 2026Final
Citation 1, item 2
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Sep 1, 2026Final
Citation 1, item 3
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Sep 1, 2026Final

Inspection 317943256 OPENED JAN 9, 2015Closed

Follow-up · Partial · Health · 60 employees at the site · Closed Jan 14, 2015

950 Old Winston Road, Kernersville, NC 27284 · Printed Circuit Assembly (Electronic Assembly) Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 317835775 OPENED AUG 6, 2014Closed

Planned · Complete · Health · 65 employees at the site · Closed Oct 28, 2014

950 Old Winston Road, Kernersville, NC 27284 · Printed Circuit Assembly (Electronic Assembly) Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,750$1,375Sep 19, 2014Final
Citation 1, item 2
29 CFR 1910.212(b) · Machine guarding
Serious$375$350Sep 19, 2014Final
Citation 1, item 3a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$750$750Sep 19, 2014Final
Citation 1, item 3b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Sep 19, 2014Closed
Citation 2, item 1
29 CFR 1910.23(d)(1)(iv) · Guarding floor and wall openings and holes
Other-than-serious$0$0Sep 19, 2014Closed
Citation 2, item 2
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Sep 19, 2014Closed
Citation 2, item 3
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Sep 19, 2014Closed
Citation 2, item 4a
29 CFR 1910.1200(f)(10) · Hazard communication
Other-than-serious$0$0Sep 19, 2014Closed
Citation 2, item 4b
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Sep 19, 2014Closed

Inspection 317016194 OPENED MAY 8, 2013Closed

Unprogrammed related · Partial · Health · 59 employees at the site · Closed Jun 21, 2013

3024 Wake Forest Road, Raleigh, NC 27609 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 125267237 OPENED AUG 15, 1996Closed

Planned · No inspection · Safety · Closed Aug 16, 1996

3930 Arendell St, Morehead City, NC 28557 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 18523746 OPENED JUL 22, 1992Closed

Referral · Partial · Health · 145 employees at the site · Closed Nov 4, 1992

950 Old Winston Road, Kernersville, NC 27284 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1025(l)(1)(i) · Lead in general industry
Other-than-serious$0$0Sep 16, 1992Closed

Inspection 18479253 OPENED FEB 28, 1992Closed

Complaint · Complete · Safety · 90 employees at the site · Closed Oct 6, 1993

950 Old Winston Road, Kernersville, NC 27284 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.36(b)(1) · Exit route design
Serious$1,250$875Jun 25, 1992Final
Citation 1, item 1b
29 CFR 1910.36(b)(4) · Exit route design
Serious$0$0Jun 25, 1992Final
Citation 1, item 1c
29 CFR 1910.37(q)(2) · Exit routes
Serious$0$0Jun 25, 1992Final
Citation 1, item 1d
29 CFR 1910.37(f)(2) · Exit routes
Serious$0$0Jun 25, 1992Final
Citation 1, item 1e
29 CFR 1910.37(k)(2) · Exit routes
Serious$0$0Jun 25, 1992Final
Citation 1, item 1f
29 CFR 1910.38(a)(1) · Emergency action plans
Serious$0$0Jun 25, 1992Final
Citation 1, item 1g
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Serious$0$0Jun 25, 1992Final
Citation 1, item 2
29 CFR 1910.36(b)(4) · Exit route design
Serious$1,250$0Jun 25, 1992Final
Citation 1, item 3
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$750$525Jun 25, 1992Final
Citation 1, item 4
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,250$875Jun 25, 1992Final
Citation 1, item 5
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$1,250$525Jun 25, 1992Final
Citation 1, item 6a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,250$875Jun 25, 1992Final
Citation 1, item 6b
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$0$0Jun 25, 1992Final
Citation 1, item 6c
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$0$0Jun 25, 1992Final
Citation 1, item 6d
29 CFR 1910.1200(h) · Hazard communication
Serious$0$0Jun 25, 1992Final
Citation 2, item 1
29 CFR 7B0305 D
Other-than-serious$500$350Jun 25, 1992Final
Citation 2, item 2
29 CFR 1910.22(b)(2) · General requirements
Other-than-serious$0$0Jun 25, 1992Final
Citation 2, item 3
29 CFR 1910.106(e)(2)(ii) · Flammable liquids
Other-than-serious$0$0Jun 25, 1992Final
Citation 2, item 4
29 CFR 1910.134(b)(8) · Respiratory protection
Other-than-serious$0$0Jun 25, 1992Final
Citation 2, item 5
29 CFR 1910.134(b)(9) · Respiratory protection
Other-than-serious$0$0Jun 25, 1992Final
Citation 2, item 6
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Jun 25, 1992Final
Citation 2, item 7
29 CFR 1910.134(e)(5) · Respiratory protection
Other-than-serious$0$0Jun 25, 1992Final
Citation 2, item 8
29 CFR 1910.151(b) · First aid and eyewash
Other-than-serious$0$0Jun 25, 1992Final
Citation 2, item 9
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0Jun 25, 1992Final
Citation 2, item 10
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Jun 25, 1992Final
Citation 2, item 11
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Jun 25, 1992Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1025 · Lead in general industry

29 CFR 1910.1025(l)(1)(i)

(l) Employee information and training—(1) Training program. (i) Each employer who has a workplace in which there is a potential exposure to airborne lead at any level shall inform employees of the content of Appendices A and B of this regulation.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(2)(ii)

(ii) Containers. Flammable liquids shall be stored in tanks or closed containers.

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

29 CFR 1910.38 · Emergency action plans

Other printed circuit assembly (electronic assembly) manufacturing employers in North Carolina

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.