OSHA SearchOSHA records by employer

Edgewood Electric, Inc.: OSHA inspections and violations

Cincinnati, Ohio · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

13inspections
18citation items
$23,822current penalties
Aug 20, 2015last inspection

OSHA has inspected Edgewood Electric, Inc. 13 times in Ohio since 1986.

The latest one began on Aug 20, 2015, in Twinsburg.

Those inspections ended with 18 citation items: 15 serious and 3 other-than-serious.

Penalties were first proposed at $48,840 and now stand at $23,822, 51% lower after settlements or reviews.

Job-site wiring comes up most often in these citations: 4 items under 1926.405.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Edgewood Electric, Inc. averages $3,500 (1 cited inspection).

Edgewood Electric, Inc.: OSHA citation items per year, 1986 to 2015
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

260employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Edgewood Electric, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340863760 OPENED AUG 20, 2015Closed

Unprogrammed other · Partial · Safety · 11 employees at the site · Closed Feb 2, 2016

2050 E. Aurora Rd., Twinsburg, OH 44087 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,500$3,500Aug 25, 2015Final

Inspection 310474440 OPENED DEC 4, 2006Closed

Unprogrammed other · Partial · Safety · 150 employees at the site · Closed Jan 29, 2007

3232 Olentangy River Road, Columbus, OH 43202 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$975$682Dec 12, 2006Closed
Citation 1, item 2
29 CFR 1926.405(j)(1)(i) · Job-site wiring
Serious$975$682Dec 12, 2006Closed

Inspection 307882415 OPENED JUL 1, 2004Closed

Unprogrammed other · Complete · Safety · 5 employees at the site · Closed Jul 20, 2004

3232 Olentangy River Road, Columbus, OH 43202 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.302(e)(1) · Power-operated hand tools
Serious$875$612Jul 9, 2004Closed

Inspection 304620354 OPENED JUL 2, 2001Closed

Planned · Complete · Safety · 80 employees at the site · Closed Aug 9, 2001

1207 17th Street, Portsmouth, OH 45662 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 122049810 OPENED APR 29, 1999Closed

Unprogrammed other · Partial · Safety · 6 employees at the site · Closed Jul 23, 1999

2400 Spiegel Drive, Columbus, OH 43137 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$900$630May 21, 1999Closed

Inspection 302137054 OPENED JUL 14, 1998Closed

Planned · Partial · Safety · 83 employees at the site · Closed Aug 13, 1999

1 Eastwood Dr., Cincinnati, OH 45227 · OSHA's record · Phone and website on Google Maps

Incident on Jul 14, 1998: Electric shock - contact with busbar thru fish tape

An electrician was feeding a steel fish tape through a 27-millimeter conduit, wh ich was connected to a 480-volt switchboard. The tape contacted an energized bus bar, causing an electrical fault. The employee received an electric shock and wa s burned by the ensuing electric arc. He was hospitalized for his injuries.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$2,500$2,500Sep 14, 1998Closed
Citation 2, item 1
29 CFR 1926.416(a)(1) · Electrical safety in construction
Unclassified$35,000$12,500Sep 14, 1998Closed

Inspection 121902654 OPENED MAR 16, 1994Closed

Unprogrammed other · Complete · Safety · 6 employees at the site · Closed Jun 15, 1994

3232 Olentangy River Road, Columbus, OH 43202 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Serious$375$375Apr 28, 1994Closed
Citation 1, item 2
29 CFR 1926.500(b)(7) · Scope, application, and definitions applicable to this subpart
Serious$500$500Apr 28, 1994Closed

Inspection 103232492 OPENED FEB 5, 1993Closed

Planned · Complete · Safety · 4 employees at the site · Closed Apr 16, 1993

3131 Queen City Ave, Cincinnati, OH 45238 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

5 older inspections

Inspection 18054940 OPENED NOV 13, 1990Closed

Unprogrammed related · Complete · Safety · 8 employees at the site · Closed Jan 3, 1991

4510 Reading Rd, Cincinnati, OH 45226 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(i)(2)(ii) · Electrical equipment on job sites
Serious$560$280Nov 20, 1990Closed
Citation 1, item 2
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$560$280Nov 20, 1990Closed
Citation 1, item 3
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$560$280Nov 20, 1990Closed
Citation 1, item 4
29 CFR 1926.500(e)(1)(iii) · Scope, application, and definitions applicable to this subpart
Serious$240$140Nov 20, 1990Closed

Inspection 101373025 OPENED MAY 4, 1987Closed

Unprogrammed related · Complete · Safety · 12 employees at the site · Closed Aug 27, 1987

537 E. Pete Rose Way, Cincinnati, OH 45202 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(4) · Scaffolds, general requirements
Serious$320$100May 12, 1987Closed
Citation 1, item 2
29 CFR 1926.500(c)(1) · Scope, application, and definitions applicable to this subpart
Serious$640$400May 12, 1987Closed
Citation 2, item 1
29 CFR 1903.2(a)(1) · Posting of notice; availability of the Act, regulations and applicable standards
Other-than-serious$0$0May 12, 1987Closed

Inspection 101650273 OPENED APR 9, 1987Closed

Unprogrammed related · Complete · Safety · 2 employees at the site · Closed Apr 13, 1987

1717 Western Avenue, Cincinnati, OH 45407 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 101645133 OPENED JAN 7, 1987Closed

Planned · Complete · Safety · 3 employees at the site · Closed Jun 5, 1987

Corner Of Snake Rd. & University Ave., Cincinnati, OH 45221 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$360$360Jan 22, 1987Closed

Inspection 101695328 OPENED MAY 6, 1986Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jun 12, 1987

5800 Centerhill Rd., Cincinnati, OH 45232 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0May 21, 1986Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.2 · Posting of notice; availability of the Act, regulations and applicable standards

29 CFR 1903.2(a)(1)

(a)(1) Each employer shall post and keep posted a notice or notices, to be furnished by the Occupational Safety and Health Administration, U.S. Department of Labor, informing employees of the protections and obligations provided for in the Act, and that for assistance and information, including copies of the Act and of specific safety and health standards, employees should contact the employer or the nearest office of the Department of Labor. Such notice or notices shall be posted by the employer in each establishment in a conspicuous place or places where notices to employees are customarily posted. Each employer shall take steps to insure that such notices are not altered, defaced, or covered by other material.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.302 · Power-operated hand tools

29 CFR 1926.400 · Introduction

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.501 · Fall protection in construction

Other electrical contractors and other wiring installation contractors employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.