OSHA SearchOSHA records by employer

Edwards Sheet Metal Works, Inc.: OSHA inspections and violations

Fredericktown, Ohio · Metal Service Centers and Other Metal Merchant Wholesalers · NAICS 423510

3inspections
15citation items
$14,802current penalties
Sep 19, 2016last inspection

Edwards Sheet Metal Works, Inc. has 3 OSHA inspections on record in Ohio, the first in 1974.

OSHA's last visit started on Sep 19, 2016 after a complaint, in Fredericktown.

Across those inspections OSHA issued 15 citation items: 12 serious and 3 other-than-serious.

OSHA proposed $24,637 in penalties. After settlements and reviews the total is $14,802, down 40%.

Most often, OSHA cited 1910.303, electrical equipment, general requirements (3 items).

For context, across all wholesale employers the median penalty per cited inspection since 2015 is $3,422. Edwards Sheet Metal Works, Inc. averages $14,752 over 1 cited inspection in that time.

Edwards Sheet Metal Works, Inc.: OSHA citation items per year, 1974 to 2016
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

251employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Edwards Sheet Metal Works, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341781649 OPENED SEP 19, 2016Closed

Complaint · Partial · Safety · 7 employees at the site · Closed May 4, 2017

10439 Sparta Road, Fredericktown, OH 43019 · Metal Service Centers and Other Metal Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$2,138$1,283Nov 23, 2016Final
Citation 1, item 2
OSH Act Section 5(a)(1) · General Duty Clause
Serious$2,672$1,603Nov 23, 2016Final
Citation 1, item 3a
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$3,207$1,924Nov 23, 2016Final
Citation 1, item 3b
29 CFR 1910.23(d)(1) · Guarding floor and wall openings and holes
Serious$0$0Nov 23, 2016Final
Citation 1, item 4
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$1,604$962Nov 23, 2016Final
Citation 1, item 5
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$3,741$2,245Nov 23, 2016Final
Citation 1, item 6
29 CFR 1910.219(f)(1) · Belts, pulleys and power-transmission parts
Serious$2,672$1,603Nov 23, 2016Final
Citation 1, item 7
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Serious$1,604$962Nov 23, 2016Final
Citation 1, item 8a
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$1,604$962Nov 23, 2016Final
Citation 1, item 8b
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$0$0Nov 23, 2016Final
Citation 1, item 9
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$1,604$962Nov 23, 2016Final
Citation 1, item 10
29 CFR 1910.305(b)(1)(i) · Electrical wiring methods
Serious$3,741$2,245Nov 23, 2016Final
Citation 2, item 1
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 23, 2016Final

Inspection 215150590 OPENED MAR 31, 1975Closed

Follow-up · Complete · Safety · 9 employees at the site · Closed Mar 10, 1984

325 North Main, Fredericktown, OH 43019 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 215149923 OPENED DEC 10, 1974Closed

Planned · Complete · Safety · 9 employees at the site · Closed Mar 10, 1984

325 North Main, Fredericktown, OH 43019 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$50$50Dec 18, 1974Closed
Citation 1, item 2 Other-than-serious$0$0Dec 18, 1974Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(1)

(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.

29 CFR 1910.212(a)(3)(ii)

(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.309

OSH Act Section 5 · General Duty Clause

Other metal service centers and other metal merchant wholesalers employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.