OSHA SearchOSHA records by employer

Electronic Controls Design Inc: OSHA inspections and violations

Mulino, Oregon · Bare Printed Circuit Board Manufacturing · NAICS 334412

6inspections
26citation items
$3,150current penalties
Sep 25, 2017last inspection

Since 1995, OSHA inspectors have visited Electronic Controls Design Inc in Oregon 6 times.

The most recent inspection opened on Sep 25, 2017 as a planned inspection, in Milwaukie.

In all, OSHA issued 26 citation items: 13 serious, 2 repeat and 11 other-than-serious.

The proposed penalties came to $3,660; today they stand at $3,150, 14% less.

The rule cited most here is 1910.1025 (lead in general industry), 8 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Electronic Controls Design Inc averages $100 across 1 cited inspection.

Electronic Controls Design Inc also files yearly injury logs with OSHA, summarized below.

Electronic Controls Design Inc: OSHA citation items per year, 1995 to 2017
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

383employers cited

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Electronic Controls Design Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342659109 OPENED SEP 25, 2017Closed

Planned · Complete · Health · 18 employees at the site · Closed Mar 19, 2018

4287 Se International Way Ste B, Milwaukie, OR 97222 · Irradiation Apparatus Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1025(l)(1)(i) · Lead in general industry
Serious$100$100Oct 20, 2017Final
Citation 1, item 1b
29 CFR 1910.1025(d)(2) · Lead in general industry
Serious$0$0Oct 20, 2017Final

Inspection 308252675 OPENED MAR 15, 2005Closed

Planned · No inspection · Safety · Closed Mar 15, 2005

13626 S Freeman Rd, Mulino, OR 97042 · Bare Printed Circuit Board Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302822333 OPENED MAY 27, 1999Closed

Planned · Complete · Health · 72 employees at the site · Closed May 2, 2000

13626 S Freeman Rd, Mulino, OR 97042 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$210$210Jul 14, 1999Closed
Citation 1, item 2a
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$300$240Jul 14, 1999Final
Citation 1, item 2b Serious$0$0Jul 14, 1999Final
Citation 2, item 3
29 CFR 1910.1025(l)(1)(i) · Lead in general industry
Repeat$600$375Jul 14, 1999Final
Citation 2, item 4
29 CFR 1910.1025(h)(1) · Lead in general industry
Repeat$600$375Jul 14, 1999Final
Citation 3, item 5
29 CFR 1910.1450(e)(1) · Occupational exposure to hazardous chemicals in laboratories
Other-than-serious$0$0Jul 14, 1999Closed
Citation 3, item 6
29 CFR 1910.303(g)(1)(iii) · Electrical equipment, general requirements
Other-than-serious$0$0Jul 14, 1999Closed
Citation 3, item 7
29 CFR 1910.1200(f)(6) · Hazard communication
Other-than-serious$0$0Jul 14, 1999Closed
Citation 3, item 8
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Jul 14, 1999Closed
Citation 3, item 9 Other-than-serious$0$0Jul 14, 1999Closed
Citation 3, item 10
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0Jul 14, 1999Closed

Inspection 302516836 OPENED DEC 23, 1998Closed

Referral · Partial · Health · 75 employees at the site · Closed Jun 17, 1999

13626 S Freeman Rd, Mulino, OR 97042 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1025(h)(1) · Lead in general industry
Serious$500$500Feb 11, 1999Closed
Citation 1, item 1b
29 CFR 1910.1025(g)(2)(ii) · Lead in general industry
Serious$0$0Feb 11, 1999Closed
Citation 1, item 2
29 CFR 1910.1025(l)(1)(i) · Lead in general industry
Serious$300$300Feb 11, 1999Closed

Inspection 302515598 OPENED DEC 21, 1998Closed

Referral · Partial · Health · 50 employees at the site · Closed Jun 17, 1999

4287 Se International Way #a, Milwaukie, OR 97222 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1025(l)(1)(i) · Lead in general industry
Serious$165$165Feb 11, 1999Closed

Inspection 126688746 OPENED AUG 24, 1995Closed

Complaint · Partial · Health · 76 employees at the site · Closed Feb 21, 1996

13626 S Freeman Rd, Mulino, OR 97042 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$105$105Dec 26, 1995Closed
Citation 1, item 2 Serious$195$195Dec 26, 1995Closed
Citation 1, item 3 Serious$195$195Dec 26, 1995Closed
Citation 1, item 4
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$195$195Dec 26, 1995Closed
Citation 2, item 5
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Other-than-serious$0$0Dec 26, 1995Closed
Citation 2, item 6 Other-than-serious$195$195Dec 26, 1995Closed
Citation 2, item 7
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Dec 26, 1995Closed
Citation 2, item 8 Other-than-serious$0$0Dec 26, 1995Closed
Citation 2, item 9
29 CFR 1910.134(f)(5)(i) · Respiratory protection
Other-than-serious$0$0Dec 26, 1995Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2016, the Milwaukie site logged 0 recordable injuries or illnesses among about 18 workers: 0.0 per 100 full-time workers, against a median of 0.3 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Electronic Controls Design
Milwaukie · 2016
18 000.00.3

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1025 · Lead in general industry

29 CFR 1910.1025(d)(2)

(2) Initial determination. Each employer who has a workplace or work operation covered by this standard shall determine if any exployee may be exposed to lead at or above the action level.

29 CFR 1910.1025(g)(2)(ii)

(ii) The employer shall provide for the cleaning, laundering, or disposal of protective clothing and equipment required by paragraph (g)(1) of this section.

29 CFR 1910.1025(h)(1)

(h) Housekeeping—(1) Surfaces. All surfaces shall be maintained as free as practicable of accumulations of lead.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.1450 · Occupational exposure to hazardous chemicals in laboratories

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.94 · Ventilation

29 CFR 7010.7650

29 CFR 7020.1230

29 CFR 7020.1270

29 CFR 7020.1610

29 CFR 7020.2210

29 CFR 7020.2930

Other bare printed circuit board manufacturing employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.