OSHA SearchOSHA records by employer

Elevation Construction and Development LLC: OSHA inspections and violations

Pittsburgh, Pennsylvania · Residential Remodelers · NAICS 236118

1inspections
9citation items
$3,490current penalties
Apr 12, 2019last inspection

OSHA inspectors have visited Elevation Construction and Development LLC in Pennsylvania one time.

It opened on Apr 12, 2019 as a planned inspection, in Pittsburgh.

In all, OSHA issued 9 citation items: 8 serious and 1 other-than-serious.

The proposed penalties came to $6,820; today they stand at $3,490, 49% less.

The rule cited most here is 1926.405 (job-site wiring), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Elevation Construction and Development LLC averages $3,490 across 1 cited inspection.

Elevation Construction and Development LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

300employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Elevation Construction and Development LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343929907 OPENED APR 12, 2019Closed

Planned · Complete · Safety · 4 employees at the site · Closed Dec 5, 2022

806, 808, 810 And 812 Middle Street, Pittsburgh, PA 15212 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$1,705$900May 6, 2019Final
Citation 1, item 1b
29 CFR 1926.405(a)(2)(ii)(i) · Job-site wiring
Serious$0$0May 6, 2019Final
Citation 1, item 1c
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$0$0May 6, 2019Final
Citation 1, item 1d
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$0$0May 6, 2019Final
Citation 1, item 1e
29 CFR 1926.405(e)(1) · Job-site wiring
Serious$0$0May 6, 2019Final
Citation 1, item 2
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$2,842$1,430May 6, 2019Final
Citation 1, item 3a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,273$1,160May 6, 2019Final
Citation 1, item 3b
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Serious$0$0May 6, 2019Final
Citation 2, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Other-than-serious$0$0May 6, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(ii)

(ii) One stairrail system along each unprotected side or edge.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

Other residential remodelers employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.