Inspection 346695711 OPENED MAY 10, 2023Closed
150 Emerson Bypass Rd, Russellville, KY 42276 · Motor and Generator Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Russellville, Kentucky · Motor and Generator Manufacturing · NAICS 335312
Since 1973, OSHA inspectors have visited Emerson Electric Co in Kentucky 13 times.
The most recent inspection opened on May 10, 2023 after a complaint, in Russellville.
In all, OSHA issued 44 citation items: 31 serious and 13 other-than-serious.
The proposed penalties came to $101,240; today they stand at $79,490, 21% less.
The rule cited most here is 1910.146 (permit-required confined spaces), 13 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Emerson Electric Co averages $36,025 across 2 cited inspections.
1 inspection on this page followed a fatal incident.
Kentucky · latest 90 days of OSHA records
184employers cited
Get notified the morning OSHA posts each new citation in Kentucky: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Kentucky
Checking a subcontractor, a client or your own company? Watch Emerson Electric Co and get notified the morning OSHA posts a new citation for it.
Watch this companyOSHA records show Emerson Electric Co at 4 sites in 2 states. Together they've had 16 inspections and $84,105 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 4 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
See plans150 Emerson Bypass Rd, Russellville, KY 42276 · Motor and Generator Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
150 Emerson Bypass Road, Russellville, KY 42276 · Motor and Generator Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.28(b)(1)(i) · Fall protection in general industry |
Serious | $3,750 | $3,750 | Nov 5, 2021 | Final |
| Citation 1, item 2a 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $6,300 | $6,300 | Nov 5, 2021 | Final |
| Citation 1, item 2b 29 CFR 1910.147(f)(1)(ii) · Lockout/tagout |
Serious | $2,250 | $2,250 | Nov 5, 2021 | Final |
| Citation 1, item 3 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $3,750 | $3,750 | Nov 5, 2021 | Final |
| Citation 2, item 1 29 CFR 1910.22(a)(3) · Walking-working surfaces |
Other-than-serious | $0 | $0 | Nov 5, 2021 | Final |
150 Emerson By-pass Rd, Russellville, KY 42276 · Motor and Generator Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Dec 5, 2020 (fatal): Employee is killed from incident on machine
At approximately 12:00 a.m. on December 5, 2020, an employee who was a maintenance employee, was working on a machine. Allegedly the CO meter on this machine was out (it was blinking red), other employees found the employee unresponsive by the machine. EMS was called and the employee was taken to a local hospital, where the employee died.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.146(d)(3)(iv) · Permit-required confined spaces |
Serious | $7,000 | $7,000 | Jun 3, 2021 | Final |
| Citation 1, item 2 29 CFR 1910.146(d)(3)(vi) · Permit-required confined spaces |
Serious | $7,000 | $0 | Jun 3, 2021 | Final |
| Citation 1, item 3 29 CFR 1910.146(d)(4)(i) · Permit-required confined spaces |
Serious | $7,000 | $7,000 | Jun 3, 2021 | Final |
| Citation 1, item 4 29 CFR 1910.146(d)(5)(i) · Permit-required confined spaces |
Serious | $7,000 | $7,000 | Jun 3, 2021 | Final |
| Citation 1, item 5 29 CFR 1910.146(d)(5)(ii) · Permit-required confined spaces |
Serious | $7,000 | $0 | Jun 3, 2021 | Final |
| Citation 1, item 6 29 CFR 1910.146(d)(9) · Permit-required confined spaces |
Serious | $7,000 | $7,000 | Jun 3, 2021 | Final |
| Citation 1, item 7a 29 CFR 1910.146(f)(2) · Permit-required confined spaces |
Serious | $7,000 | $3,500 | Jun 3, 2021 | Final |
| Citation 1, item 7b 29 CFR 1910.146(f)(10) · Permit-required confined spaces |
Serious | $0 | $0 | Jun 3, 2021 | Final |
| Citation 1, item 7c 29 CFR 1910.146(f)(12) · Permit-required confined spaces |
Serious | $0 | $0 | Jun 3, 2021 | Final |
| Citation 1, item 8 29 CFR 1910.146(g)(2)(i) · Permit-required confined spaces |
Serious | $7,000 | $7,000 | Jun 3, 2021 | Final |
| Citation 1, item 9 29 CFR 1910.146(j)(2) · Permit-required confined spaces |
Serious | $7,000 | $7,000 | Jun 3, 2021 | Final |
| Citation 1, item 10a 29 CFR 1910.146(k)(3)(i) · Permit-required confined spaces |
Serious | $7,000 | $7,000 | Jun 3, 2021 | Final |
| Citation 1, item 10b 29 CFR 1910.146(k)(3)(ii) · Permit-required confined spaces |
Serious | $0 | $0 | Jun 3, 2021 | Final |
| Citation 1, item 11 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $7,000 | $3,500 | Jun 3, 2021 | Final |
150 Emerson Bypass Rd, Russellville, KY 42276 · Motor and Generator Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
150 Emerson By-pass Rd, Russellville, KY 42276 · Motor and Generator Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 4 29 CFR 1910.1200(e)(4) · Hazard communication |
Serious | $2,125 | $2,125 | Jun 20, 2008 | Final |
150 Emerson Bypass Rd, Russellville, KY 42276 · Motor and Generator Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.217(c)(1)(i) · Mechanical power presses |
Serious | $1,500 | $750 | Jul 27, 2005 | Final |
150 Emerson Bypass Rd, Russellville, KY 42276 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $1,300 | $1,300 | Aug 4, 1995 | Closed |
| Citation 1, item 1b 29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Aug 4, 1995 | Closed |
| Citation 1, item 2 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $1,625 | $1,625 | Aug 4, 1995 | Closed |
Us Highway 68 West, Russellville, KY 42276 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1163 Algonquin Pkwy., Louisville, KY 40208 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Us Highway 68 West, Russellville, KY 42276 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $240 | $240 | Oct 16, 1989 | Closed |
| Citation 1, item 2 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $300 | $300 | Oct 16, 1989 | Closed |
| Citation 1, item 3a 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $300 | $300 | Oct 16, 1989 | Closed |
| Citation 1, item 3b 29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Oct 16, 1989 | Closed |
| Citation 2, item 1 29 CFR 1910.23(d)(1)(iv) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Oct 16, 1989 | Closed |
| Citation 2, item 2 29 CFR 1910.212(a)(1) · Machine guarding |
Other-than-serious | $0 | $0 | Oct 16, 1989 | Closed |
| Citation 2, item 3 29 CFR 1910.303(f) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Oct 16, 1989 | Closed |
| Citation 2, item 4 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Oct 16, 1989 | Closed |
Highway 68, Russellville, KY 42276 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $240 | $240 | Apr 18, 1986 | Closed |
| Citation 1, item 1b 29 CFR 1910.215(a)(2) · Grinders and abrasive wheels |
Serious | $0 | $0 | Apr 18, 1986 | Closed |
| Citation 2, item 1 29 CFR 1910.132(a) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Apr 18, 1986 | Closed |
| Citation 2, item 2 29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Apr 18, 1986 | Closed |
| Citation 2, item 3 29 CFR 2018003 |
Other-than-serious | $0 | $0 | Apr 18, 1986 | Closed |
Highway 68 West, Russellville, KY 42276 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.95(a) · Noise |
Serious | $560 | $560 | Jun 7, 1982 | Contested |
| Citation 1, item 1b 29 CFR 1910.95(b)(1) · Noise |
Serious | $0 | $0 | Jun 7, 1982 | Contested |
| Citation 2, item 1 29 CFR 1910.151(d) · First aid and eyewash |
Other-than-serious | $0 | $0 | Jun 7, 1982 | Contested |
| Citation 2, item 2 29 CFR 1910.108(c)(5) · [Reserved] |
Other-than-serious | $0 | $0 | Jun 7, 1982 | Contested |
| Citation 2, item 3 29 CFR 1910.108(c)(2)(i) · [Reserved] |
Other-than-serious | $0 | $0 | Jun 7, 1982 | Contested |
| Citation 2, item 4 29 CFR 1910.108(f)(4) · [Reserved] |
Other-than-serious | $0 | $0 | Jun 7, 1982 | Contested |
| Citation 2, item 5 29 CFR 1910.134(f)(1) · Respiratory protection |
Other-than-serious | $0 | $0 | Jun 7, 1982 | Contested |
Hopkinsville Road, Russellville, KY 42276 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1200(e)(4)
(4) The employer shall make the written hazard communication program available, upon request, to employees, their designated representatives, the Assistant Secretary and the Director, in accordance with the requirements of § 1910.1020(e).
29 CFR 1910.132(a)
(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.
29 CFR 1910.134(f)(1)
(1) Normal breathing. In a normal standing position, without talking, the subject shall breathe normally.
Alert subscribers get notified of each newly cited employer in Kentucky the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.