OSHA has inspected Empire Coating Inc 4 times in New York since 1994.
The latest one began on Feb 17, 2026 after a complaint, in Albion; the case is still open.
Those inspections ended with 10 citation items: 6 serious and 4 other-than-serious.
Penalties were first proposed at $12,219 and now stand at $8,415, 31% lower after settlements or reviews.
Spray painting and finishing comes up most often in these citations: 4 items under 1910.107.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Empire Coating Inc averages $2,690 (1 cited inspection).
Empire Coating Inc also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
New York · latest 90 days of OSHA records
353employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
Complaint · Partial · Safety · 37 employees at the site · Closed Jun 18, 2004
215 West Avenue, Albion, NY 14411 · Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers · OSHA's record · Phone and website on Google Maps
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Albion site logged 3 recordable injuries or illnesses among about 86 workers: 4.2 per 100 full-time workers, against a median of 2.0 for its industry. Those cases cost 38 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Empire Coating Inc
Albion · 2025
86
3
1
4.2
2.0
Empire Coating, Inc.
Albion · 2022
76
2
0
2.6
2.0
Included with any plan: 1 more yearly log from these sites, back to 2022, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(b)(5)(iv)
(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.
29 CFR 1910.107(b)(9)
(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.