OSHA SearchOSHA records by employer

Empire Construction Incorporated: OSHA inspections and violations

Saint Paul, Minnesota · Roofing Contractors · NAICS 238160

4inspections
8citation items
$3,052current penalties
Apr 22, 2020last inspection

Since 2015, OSHA inspectors have visited Empire Construction Incorporated in Minnesota 4 times.

The most recent inspection opened on Apr 22, 2020 after a complaint, in Saint Paul.

In all, OSHA issued 8 citation items: 7 serious and 1 other-than-serious.

The proposed penalties came to $3,925; today they stand at $3,052, 22% less.

The rule cited most here is 1926.501 (fall protection in construction), 6 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Empire Construction Incorporated averages $763 across 4 cited inspections.

Empire Construction Incorporated: OSHA citation items per year, 2015 to 2020
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

380employers cited

34 of them in the same industry

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Empire Construction Incorporated and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344729496 OPENED APR 22, 2020Closed

Complaint · Partial · Safety · 12 employees at the site · Closed Mar 2, 2021

1700 Wynne Ave, Saint Paul, MN 55108 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(c)(1)(vi) · Fire protection
Serious$225$225May 6, 2020Final
Citation 1, item 2
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,050$1,050May 6, 2020Final

Inspection 343175501 OPENED MAY 15, 2018Closed

Complaint · Partial · Safety · 11 employees at the site · Closed Jun 29, 2018

3600 W St Germain St, Saint Cloud, MN 56301 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$825$578Jun 8, 2018Final
Citation 1, item 1b
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$0$0Jun 8, 2018Final

Inspection 341765329 OPENED JUL 7, 2016Closed

Planned · Complete · Safety · 6 employees at the site · Closed Oct 24, 2016

2301 Como Ave, Saint Paul, MN 55108 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,050$735Sep 15, 2016Final
Citation 1, item 1b
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$0$0Sep 15, 2016Final

Inspection 317957728 OPENED JAN 27, 2015Closed

Planned · Complete · Safety · 4 employees at the site · Closed May 19, 2015

201 Lyndale Ave S, Faribault, MN 55021 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$675$405Feb 11, 2015Final
Citation 2, item 1
29 CFR 1926.152(a)(1) · Flammable liquids
Other-than-serious$100$60Feb 11, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(vi)

(vi) A fire extinguisher, rated not less than 10B, shall be provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas are being used on the jobsite. This requirement does not apply to the integral fuel tanks of motor vehicles.

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.152(a)(1)

(a) General requirements. (1) Only approved containers and portable tanks shall be used for storage and handling of flammable liquids. Approved safety cans or Department of Transportation approved containers shall be used for the handling and use of flammable liquids in quantities of 5 gallons or less, except that this shall not apply to those flammable liquid materials which are highly viscid (extremely hard to pour), which may be used and handled in original shipping containers. For quantities of one gallon or less, the original container may be used, for storage, use and handling of flammable liquids.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

Other roofing contractors employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.