Inspection 347253676 OPENED FEB 2, 2024Closed
1455 Buffalo Road, Titusville, FL 32796 · Adhesive Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Titusville, Florida · Adhesive Manufacturing · NAICS 325520
Since 2020, OSHA inspectors have visited Engineered Bonding Solutions, LLC in Florida 2 times.
The most recent inspection opened on Feb 2, 2024 after a complaint, in Titusville.
In all, OSHA issued 6 citation items: 2 serious and 4 other-than-serious.
The proposed penalties came to $9,254; today they stand at $5,552, 40% less.
The rule cited most here is 1910.305 (electrical wiring methods), 2 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Engineered Bonding Solutions, LLC averages $5,552 across 1 cited inspection.
Want to know if OSHA cites Engineered Bonding Solutions, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company1455 Buffalo Road, Titusville, FL 32796 · Adhesive Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
801 Marina Rd., Titusville, FL 32796 · Adhesive Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 OSH Act Section 5(a)(1) · General Duty Clause |
Serious | $5,398 | $3,239 | Jun 1, 2020 | Final |
| Citation 1, item 2 29 CFR 1910.28(b)(1)(i)(c) · Fall protection in general industry |
Serious | $3,856 | $2,314 | Jun 1, 2020 | Final |
| Citation 2, item 1 29 CFR 1910.38(b) · Emergency action plans |
Other-than-serious | $0 | $0 | Jun 1, 2020 | Final |
| Citation 2, item 2 29 CFR 1910.176(c) · Material storage and aisles |
Other-than-serious | $0 | $0 | Jun 1, 2020 | Final |
| Citation 2, item 3 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jun 1, 2020 | Final |
| Citation 2, item 4 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jun 1, 2020 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.176(c)
(c) Housekeeping. Storage areas shall be kept free from accumulation of materials that constitute hazards from tripping, fire, explosion, or pest harborage. Vegetation control will be exercised when necessary.
29 CFR 1910.28(b)(1)(i)(c)
(C) Personal fall protection systems, such as personal fall arrest, travel restraint, or positioning systems.
29 CFR 1910.305(g)(1)(iv)(a)
(A) As a substitute for the fixed wiring of a structure;
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.