Inspection 348904855 OPENED APR 23, 2026Closed
911 Industrial Dr Sw, Conover, NC 28613 · Industrial Valve Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Conover, North Carolina · Industrial Valve Manufacturing · NAICS 332911
Engineered Controls International, Inc. has 8 OSHA inspections on record in North Carolina, the first in 1994.
OSHA's last visit started on Apr 23, 2026 to follow up on an earlier case, in Conover.
Across those inspections OSHA issued 39 citation items: 14 serious, 2 repeat and 23 other-than-serious.
OSHA proposed $23,728 in penalties. After settlements and reviews the total is $18,201, down 23%.
Most often, OSHA cited 1910.212, machine guarding (5 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Engineered Controls International, Inc. averages $3,975 over 2 cited inspections in that time.
Engineered Controls International, Inc. also files yearly injury logs with OSHA, summarized below.
North Carolina · latest 90 days of OSHA records
236employers cited
Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in North Carolina
Checking a subcontractor, a client or your own company? Watch Engineered Controls International, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company911 Industrial Dr Sw, Conover, NC 28613 · Industrial Valve Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
911 Industrial Dr Sw, Conover, NC 28613 · Industrial Valve Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.95(b)(1) · Noise |
Other-than-serious | $0 | $0 | Jan 7, 2026 | Final |
| Citation 1, item 2 29 CFR 1910.95(d)(1) · Noise |
Other-than-serious | $0 | $0 | Jan 7, 2026 | Final |
| Citation 1, item 3 29 CFR 1910.95(l)(1) · Noise |
Other-than-serious | $0 | $0 | Jan 7, 2026 | Final |
| Citation 1, item 4 29 CFR 1910.134(d)(1)(ii) · Respiratory protection |
Other-than-serious | $0 | $0 | Jan 7, 2026 | Final |
1239 Rock Creek Dairy Road, Whitsett, NC 27377 · Industrial Valve Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $6,300 | $6,300 | Jun 15, 2022 | Final |
| Citation 1, item 2a 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $975 | $975 | Jun 15, 2022 | Final |
| Citation 1, item 2b 29 CFR 1910.212(b) · Machine guarding |
Serious | $0 | $0 | Jun 15, 2022 | Final |
| Citation 1, item 3a 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Serious | $675 | $675 | Jun 15, 2022 | Final |
| Citation 1, item 3b 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $0 | $0 | Jun 15, 2022 | Final |
| Citation 2, item 1 29 CFR 1910.107(g)(7) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Jun 15, 2022 | Final |
| Citation 2, item 2 29 CFR 1910.1026(d)(1) · Hexavalent chromium |
Other-than-serious | $0 | $0 | Jun 15, 2022 | Final |
| Citation 2, item 3 29 CFR 1910.1026(l)(1)(iii) · Hexavalent chromium |
Other-than-serious | $0 | $0 | Jun 15, 2022 | Final |
1239 Rock Dairy Creek Road, Whitsett, NC 27377 · Industrial Valve Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Repeat | $6,300 | $4,000 | Dec 6, 2007 | Closed |
| Citation 2, item 1 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Repeat | $100 | $100 | Dec 6, 2007 | Closed |
3181 Lear Drive, Burlington, NC 27215 · Industrial Valve Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $488 | $300 | Dec 18, 2006 | Closed |
| Citation 1, item 2 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $1,138 | $800 | Dec 18, 2006 | Closed |
| Citation 1, item 3a 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $813 | $650 | Dec 18, 2006 | Closed |
| Citation 1, item 5 29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts |
Serious | $813 | $650 | Dec 18, 2006 | Closed |
| Citation 2, item 1 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Dec 18, 2006 | Closed |
| Citation 2, item 2 29 CFR 1910.132(f)(4) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Dec 18, 2006 | Closed |
| Citation 2, item 3 29 CFR 1910.305(a)(1)(i) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Dec 18, 2006 | Closed |
911 Industrial Drive S.w., Conover, NC 28613 · Industrial Valve Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.107(g)(2) · Spray painting and finishing |
Serious | $125 | $125 | Jun 1, 2005 | Closed |
| Citation 2, item 1 29 CFR 1910.38(a)(5)(iii) · Emergency action plans |
Other-than-serious | $0 | $0 | Jun 1, 2005 | Closed |
| Citation 2, item 2 29 CFR 1910.124(h)(4) · General requirements for dipping and coating operations |
Other-than-serious | $0 | $0 | Jun 1, 2005 | Closed |
| Citation 2, item 3 29 CFR 1910.157(g)(2) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Jun 1, 2005 | Closed |
| Citation 2, item 4 29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jun 1, 2005 | Closed |
| Citation 2, item 5 29 CFR 1910.304(e)(1)(via) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Jun 1, 2005 | Closed |
| Citation 2, item 6 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jun 1, 2005 | Closed |
| Citation 2, item 7a 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Jun 1, 2005 | Closed |
| Citation 2, item 7b 29 CFR 1910.1200(f)(5)(ii) · Hazard communication |
Other-than-serious | $0 | $0 | Jun 1, 2005 | Closed |
| Citation 2, item 8 29 CFR 1910.1200(h)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Jun 1, 2005 | Closed |
100 Rego Dr., Elon College, NC 27244 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Serious | $963 | $963 | Nov 8, 1996 | Closed |
| Citation 1, item 2 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $1,375 | $1,375 | Nov 8, 1996 | Closed |
| Citation 1, item 3 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Serious | $413 | $413 | Nov 8, 1996 | Closed |
| Citation 2, item 1a 29 CFR 1910.134(b)(1) · Respiratory protection |
Other-than-serious | $0 | $0 | Nov 8, 1996 | Closed |
| Citation 2, item 1b 29 CFR 1910.134(b)(3) · Respiratory protection |
Other-than-serious | $0 | $0 | Nov 8, 1996 | Closed |
| Citation 2, item 1c 29 CFR 1910.134(b)(6) · Respiratory protection |
Other-than-serious | $0 | $0 | Nov 8, 1996 | Closed |
| Citation 2, item 2 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Nov 8, 1996 | Closed |
1239 Rock Creek Dairy Road, Whittsett, NC 27377 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $3,250 | $875 | Apr 18, 1994 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2020, the Whitsett site logged 6 recordable injuries or illnesses among about 140 workers: 4.5 per 100 full-time workers, against a median of 2.4 for its industry. Those cases cost 175 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Rock Creek Plant Whitsett · 2020 | 140 | 6 | 2 | 4.5 | 2.4 |
| Conover Regulator Plant Conover · 2020 | 51 | 1 | 0 | 1.6 | 2.4 |
| Burlington - Cryo Flow Burlington · 2020 | 24 | 0 | 0 | 0.0 | 2.4 |
Included with any plan: 9 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1026(d)(1)
(d) Exposure determination—(1) General. Each employer who has a workplace or work operation covered by this section shall determine the 8-hour TWA exposure for each employee exposed to chromium (VI). This determination shall be made in accordance with either paragraph (d)(2) or paragraph (d)(3) of this section.
29 CFR 1910.1026(l)(1)(iii)
(l) Communication of chromium (VI) hazards to employees—(1) Hazard communication—general—(i) Chemical manufacturers, importers, distributors and employers shall comply with all requirements of the Hazard Communication Standard (HCS) (§ 1910.1200) for chromium (VI).
29 CFR 1910.107(g)(2)
(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.
Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.