OSHA SearchOSHA records by employer

Englander Enterprises, Inc.: OSHA inspections and violations

Clearwater, Florida · Printed Circuit Assembly (Electronic Assembly) Manufacturing · NAICS 334418

1inspections
5citation items
$6,365current penalties
Feb 19, 2019last inspection

Englander Enterprises, Inc. has one OSHA inspection on record in Florida.

OSHA opened it on Feb 19, 2019 after a complaint, in Clearwater.

From that inspection OSHA issued 5 citation items: 5 serious.

OSHA proposed $10,608 in penalties. After settlements and reviews the total is $6,365, down 40%.

Most often, OSHA cited 1910.134, respiratory protection (4 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Englander Enterprises, Inc. averages $6,365 over 1 cited inspection in that time.

Englander Enterprises, Inc.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

OSHA cited 339 employers in Florida in the latest 90 days of its records. Get each new citation in Florida by email the morning it is posted: the employer, the site address, the rules broken and the penalty.

Get Florida alerts

Checking a subcontractor, a client or your own company? Watch Englander Enterprises, Inc. and we email you the morning OSHA posts a new citation for it. Up to 25 companies on one state, 250 on all states.

Watch this company

Inspection history

Inspection 343791760 OPENED FEB 19, 2019Closed

Complaint · Partial · Health · 48 employees at the site · Closed Sep 26, 2019

703 Grand Central Street, Clearwater, FL 33756 · Printed Circuit Assembly (Electronic Assembly) Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$3,978$2,387Aug 9, 2019Final
Citation 1, item 1b
29 CFR 1910.134(d)(1)(i) · Respiratory protection
Serious$0$0Aug 9, 2019Final
Citation 1, item 1c
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Aug 9, 2019Final
Citation 1, item 1d
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Aug 9, 2019Final
Citation 1, item 2
29 CFR 1910.1025(d)(2) · Lead in general industry
Serious$6,630$3,978Aug 9, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1025 · Lead in general industry

29 CFR 1910.1025(d)(2)

(2) Initial determination. Each employer who has a workplace or work operation covered by this standard shall determine if any exployee may be exposed to lead at or above the action level.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(d)(1)(i)

(1) General requirements. (i) The employer shall select and provide an appropriate respirator based on the respiratory hazard(s) to which the worker is exposed and workplace and user factors that affect respirator performance and reliability.

Other printed circuit assembly (electronic assembly) manufacturing employers in Florida

Alert subscribers get each newly cited employer in Florida by email the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.