OSHA SearchOSHA records by employer

Erasmo Charles Gonzalez: OSHA inspections and violations

Pike Road, Alabama · Siding Contractors · NAICS 238170

1inspections
5citation items
$7,500current penalties
Jul 21, 2016last inspection

Erasmo Charles Gonzalez has one OSHA inspection on record in Alabama.

OSHA opened it on Jul 21, 2016 as a planned inspection, in Pike Road.

From that inspection OSHA issued 5 citation items: 5 serious.

OSHA proposed $14,434 in penalties. After settlements and reviews the total is $7,500, down 48%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Erasmo Charles Gonzalez averages $7,500 over 1 cited inspection in that time.

Erasmo Charles Gonzalez: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Alabama · latest 90 days of OSHA records

99employers cited

Get notified the morning OSHA posts each new citation in Alabama: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alabama

Checking a subcontractor, a client or your own company? Watch Erasmo Charles Gonzalez and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341657484 OPENED JUL 21, 2016Closed

Planned · Partial · Safety · 3 employees at the site · Closed Oct 25, 2016

8912 Big Horn Trail, Pike Road, AL 36064 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$2,673$1,500Aug 11, 2016Final
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,673$1,500Aug 11, 2016Final
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,673$1,500Aug 11, 2016Final
Citation 1, item 4
29 CFR 1926.452(j)(1) · Rules for each type of scaffold
Serious$2,673$1,500Aug 11, 2016Final
Citation 1, item 5
29 CFR 1926.452(k)(5) · Rules for each type of scaffold
Serious$3,742$1,500Aug 11, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(5)(ii)

(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

29 CFR 1926.452 · Rules for each type of scaffold

Other siding contractors employers in Alabama