OSHA SearchOSHA records by employer

Eurostone LLC: OSHA inspections and violations

Murfreesboro, Tennessee · Cut Stone and Stone Product Manufacturing · NAICS 327991

3inspections
55citation items
$39,775current penalties
Jul 16, 2026last inspection

Since 2024, OSHA inspectors have visited Eurostone LLC in Tennessee 3 times.

The most recent inspection opened on Jul 16, 2026 to follow up on an earlier case, in Murfreesboro and is still open.

In all, OSHA issued 55 citation items: 43 serious, 6 repeat and 6 other-than-serious.

The penalties, $39,775 in total, stand where OSHA first set them.

The rule cited most here is 1910.1053 (silica dust in general industry), 12 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Eurostone LLC averages $13,258 across 3 cited inspections.

Eurostone LLC: OSHA citation items per year, 2024 to 2026
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

334employers cited

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Eurostone LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 349055814 OPENED JUL 16, 2026Open

Follow-up · Partial · Health · 10 employees at the site · Open

805 Nw Broad Street, Murfreesboro, TN 37129 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$1,600$1,600Sep 24, 2026Final
Citation 1, item 1b Serious$0$0Sep 24, 2026Final
Citation 1, item 1c Serious$0$0Sep 24, 2026Final
Citation 1, item 1d Serious$0$0Sep 24, 2026Final
Citation 1, item 2a
29 CFR 1910.134(c)(3) · Respiratory protection
Serious$1,600$1,600Sep 24, 2026Final
Citation 1, item 2b
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Sep 24, 2026Final
Citation 1, item 2c
29 CFR 1910.134(g)(1)(iii) · Respiratory protection
Serious$0$0Sep 24, 2026Final
Citation 1, item 2d
29 CFR 1910.134(k)(1) · Respiratory protection
Serious$0$0Sep 24, 2026Final
Citation 1, item 3a
29 CFR 1910.1053(d)(4) · Silica dust in general industry
Serious$1,600$1,600Sep 24, 2026Final
Citation 1, item 3b
29 CFR 1910.1053(f)(2)(ii) · Silica dust in general industry
Serious$0$0Sep 24, 2026Final
Citation 1, item 3c
29 CFR 1910.1053(j)(3)(i) · Silica dust in general industry
Serious$0$0Sep 24, 2026Final
Citation 1, item 3d
29 CFR 1910.1053(k)(1)(i) · Silica dust in general industry
Serious$0$0Sep 24, 2026Final
Citation 1, item 4a
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Serious$1,600$1,600Sep 24, 2026Final
Citation 1, item 4b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Sep 24, 2026Final
Citation 2, item 1a Repeat$3,200$3,200Sep 24, 2026Final
Citation 2, item 1b Repeat$0$0Sep 24, 2026Final
Citation 2, item 2a
29 CFR 1910.134(c)(1) · Respiratory protection
Repeat$3,200$3,200Sep 24, 2026Final
Citation 2, item 2b
29 CFR 1910.134(e)(1) · Respiratory protection
Repeat$0$0Sep 24, 2026Final
Citation 2, item 3a
29 CFR 1910.1200(e)(1) · Hazard communication
Repeat$3,200$3,200Sep 24, 2026Final
Citation 2, item 3b
29 CFR 1910.1200(g)(1) · Hazard communication
Repeat$0$0Sep 24, 2026Final
Citation 3, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$100$100Sep 24, 2026Final
Citation 3, item 2a
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$100$100Sep 24, 2026Final
Citation 3, item 2b
29 CFR 1910.305(g)(1)(iv)(d) · Electrical wiring methods
Other-than-serious$0$0Sep 24, 2026Final
Citation 3, item 3
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Other-than-serious$100$100Sep 24, 2026Final

Inspection 347609026 OPENED JUL 11, 2024Open

Complaint · Partial · Safety · 16 employees at the site · Open

805 Nw Broad Street, Murfreesboro, TN 37129 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(1)(i)(a) · Fall protection in general industry
Serious$1,500$1,500Sep 25, 2024Final
Citation 1, item 2
29 CFR 1910.28(b)(2)(i) · Fall protection in general industry
Serious$2,000$2,000Sep 25, 2024Final
Citation 1, item 3a
29 CFR 1910.29(b)(1) · Fall protection systems in general industry
Serious$1,500$1,500Sep 25, 2024Final
Citation 1, item 3b
29 CFR 1910.29(b)(2)(i) · Fall protection systems in general industry
Serious$0$0Sep 25, 2024Final
Citation 1, item 4
29 CFR 1910.37(b)(5) · Exit routes
Serious$1,750$1,750Sep 25, 2024Final
Citation 1, item 5
29 CFR 1910.212(a)(5) · Machine guarding
Serious$1,500$1,500Sep 25, 2024Final
Citation 1, item 6a
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$1,750$1,750Sep 25, 2024Final
Citation 1, item 6b
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$0$0Sep 25, 2024Final
Citation 1, item 6c
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Sep 25, 2024Final
Citation 2, item 1
29 CFR 1910.178(l)(5) · Forklifts and other powered industrial trucks
Other-than-serious$125$125Sep 25, 2024Final

Inspection 347609182 OPENED JUL 11, 2024Open

Complaint · Partial · Health · 16 employees at the site · Open

805 Nw Broad Street, Murfreesboro, TN 37129 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.22(a)(3) · Walking-working surfaces
Serious$1,750$1,750Oct 29, 2024Final
Citation 1, item 1b
29 CFR 1910.28(b)(3)(i) · Fall protection in general industry
Serious$0$0Oct 29, 2024Final
Citation 1, item 2a Serious$2,000$2,000Oct 29, 2024Final
Citation 1, item 2b Serious$0$0Oct 29, 2024Final
Citation 1, item 2c Serious$0$0Oct 29, 2024Final
Citation 1, item 2d Serious$0$0Oct 29, 2024Final
Citation 1, item 3
29 CFR 1910.110(e)(4)(iii) · Storage and handling of liquefied petroleum gases
Serious$1,250$1,250Oct 29, 2024Final
Citation 1, item 4a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$1,750$1,750Oct 29, 2024Final
Citation 1, item 4b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Oct 29, 2024Final
Citation 1, item 4c
29 CFR 1910.134(d)(1)(ii) · Respiratory protection
Serious$0$0Oct 29, 2024Final
Citation 1, item 5a
29 CFR 1910.1053(c) · Silica dust in general industry
Serious$4,000$4,000Oct 29, 2024Final
Citation 1, item 5b
29 CFR 1910.1053(d)(1) · Silica dust in general industry
Serious$0$0Oct 29, 2024Final
Citation 1, item 5c
29 CFR 1910.1053(e)(1) · Silica dust in general industry
Serious$0$0Oct 29, 2024Final
Citation 1, item 5d
29 CFR 1910.1053(f)(1) · Silica dust in general industry
Serious$0$0Oct 29, 2024Final
Citation 1, item 5e
29 CFR 1910.1053(f)(2)(i) · Silica dust in general industry
Serious$0$0Oct 29, 2024Final
Citation 1, item 5f
29 CFR 1910.1053(g)(1)(i) · Silica dust in general industry
Serious$0$0Oct 29, 2024Final
Citation 1, item 5g
29 CFR 1910.1053(i)(1)(i) · Silica dust in general industry
Serious$0$0Oct 29, 2024Final
Citation 1, item 5h
29 CFR 1910.1053(j)(2) · Silica dust in general industry
Serious$0$0Oct 29, 2024Final
Citation 1, item 6a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$2,000$2,000Oct 29, 2024Final
Citation 1, item 6b
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$0$0Oct 29, 2024Final
Citation 2, item 1
29 CFR TDLWD RULE 800-01-04-.23(4)(A)
Other-than-serious$600$600May 22, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1053 · Silica dust in general industry

29 CFR 1910.1053(c)

(c) Permissible exposure limit (PEL). The employer shall ensure that no employee is exposed to an airborne concentration of respirable crystalline silica in excess of 50 µg/m 3, calculated as an 8-hour TWA.

29 CFR 1910.1053(d)(1)

(d) Exposure assessment—(1) General. The employer shall assess the exposure of each employee who is or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2) or the scheduled monitoring option in paragraph (d)(3) of this section.

29 CFR 1910.1053(d)(4)

(4) Reassessment of exposures. The employer shall reassess exposures whenever a change in the production, process, control equipment, personnel, or work practices may reasonably be expected to result in new or additional exposures at or above the action level, or when the employer has any reason to believe that new or additional exposures at or above the action level have occurred.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.29 · Fall protection systems in general industry

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.37 · Exit routes

29 CFR 1910.95 · Noise

Other cut stone and stone product manufacturing employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.