OSHA SearchOSHA records by employer

Eventquip: OSHA inspections and violations

Philadelphia, Pennsylvania · Other Foundation, Structure, and Building Exterior Contractors · NAICS 238190

1inspections
5citation items
$7,686current penalties
Apr 6, 2018last inspection

OSHA inspectors have visited Eventquip in Pennsylvania one time.

It opened on Apr 6, 2018 on a referral, in Philadelphia.

In all, OSHA issued 5 citation items: 3 serious and 2 other-than-serious.

The proposed penalties came to $11,824; today they stand at $7,686, 35% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Eventquip averages $7,686 across 1 cited inspection.

Eventquip: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

285employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Eventquip and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343077202 OPENED APR 6, 2018Closed

Referral · Partial · Safety · 25 employees at the site · Closed Nov 9, 2018

S 11th St And Flagship Ave, Philadelphia, PA 19112 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2)(iv) · Scaffolds, general requirements
Serious$4,434$2,882Sep 18, 2018Final
Citation 1, item 1b
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Sep 18, 2018Final
Citation 1, item 2a
29 CFR 1926.602(c)(1)(ii) · Earthmovers and forklifts in construction
Serious$4,434$2,882Sep 18, 2018Final
Citation 1, item 2b
29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements
Other-than-serious$0$0Sep 18, 2018Final
Citation 1, item 3
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$2,956$1,921Sep 18, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(1)(i)

(l) Operator training. (1) Safe operation. (i) The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)(iv)

(iv) Front-end loaders and similar pieces of equipment shall not be used to support scaffold platforms unless they have been specifically designed by the manufacturer for such use.

29 CFR 1926.602 · Earthmovers and forklifts in construction

Other other foundation, structure, and building exterior contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.