OSHA SearchOSHA records by employer

F and L Construction LLC: OSHA inspections and violations

Toledo, Ohio · Roofing Contractors · NAICS 238160

2inspections
5citation items
$2,400current penalties
Oct 21, 2015last inspection

F and L Construction LLC has 2 OSHA inspections on record in Ohio, the first in 1997.

OSHA's last visit started on Oct 21, 2015 on a referral, in Monclova.

Across those inspections OSHA issued 5 citation items: 4 serious and 1 other-than-serious.

OSHA proposed $4,000 in penalties. After settlements and reviews the total is $2,400, down 40%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. F and L Construction LLC averages $2,400 over 1 cited inspection in that time.

F and L Construction LLC: OSHA citation items per year, 1997 to 2015
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

260employers cited

67 of them in the same industry

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch F and L Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341001212 OPENED OCT 21, 2015Closed

Referral · Partial · Safety · 4 employees at the site · Closed Nov 18, 2016

4310 Albion Rd., Monclova, OH 43542 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$2,800$1,680Oct 30, 2015Final
Citation 1, item 1b
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$0$0Oct 30, 2015Final
Citation 1, item 1c
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Oct 30, 2015Final
Citation 1, item 2
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$1,200$720Oct 30, 2015Final

Inspection 301528527 OPENED APR 18, 1997Closed

Unprogrammed other · Partial · Safety · 10 employees at the site · Closed May 28, 1997

300 S. Byrne Rd., Toledo, OH 43615 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(a)(4) · Fire protection
Other-than-serious$0$0May 23, 1997Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(a)(4)

(4) All firefighting equipment shall be periodically inspected and maintained in operating condition. Defective equipment shall be immediately replaced.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(1)

(b) Accident prevention responsibilities. (1) It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.95 · Criteria for personal protective equipment

Other roofing contractors employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.