OSHA SearchOSHA records by employer

Fab Metal, LLC: OSHA inspections and violations

Powell, Tennessee · Sheet Metal Work Manufacturing · NAICS 332322

5inspections
24citation items
$7,300current penalties
Jan 5, 2024last inspection

Since 2000, OSHA inspectors have visited Fab Metal, LLC in Tennessee 5 times.

The most recent inspection opened on Jan 5, 2024 as a planned inspection, in Powell and is still open.

In all, OSHA issued 24 citation items: 15 serious and 9 other-than-serious.

The penalties, $7,300 in total, stand where OSHA first set them.

The rule cited most here is 1910.134 (respiratory protection), 6 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Fab Metal, LLC averages $5,800 across 1 cited inspection.

Fab Metal, LLC: OSHA citation items per year, 2000 to 2024
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

342employers cited

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Fab Metal, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347196644 OPENED JAN 5, 2024Open

Planned · Complete · Safety · 27 employees at the site · Open

1904 West Emory Road #b, Powell, TN 37849 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR TCA 50-3-105(1)
Serious$1,400$1,400Mar 14, 2024Final
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,600$1,600Mar 14, 2024Final
Citation 1, item 3
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$1,000$1,000Mar 14, 2024Final
Citation 1, item 4
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$1,000$1,000Mar 14, 2024Final
Citation 2, item 1
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Other-than-serious$200$200Mar 14, 2024Final
Citation 2, item 2a
29 CFR 1910.303(e)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$200$200Mar 14, 2024Final
Citation 2, item 2b
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Mar 14, 2024Final
Citation 2, item 3
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Other-than-serious$200$200Mar 14, 2024Final
Citation 2, item 4
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$200$200Mar 14, 2024Final

Inspection 312235856 OPENED FEB 14, 2008Closed

Complaint · Partial · Health · 40 employees at the site · Closed May 22, 2008

1904-b West Emory Road, Powell, TN 37849 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311146641 OPENED JUL 6, 2007Closed

Planned · Complete · Health · 40 employees at the site · Closed Nov 5, 2007

1904-b West Emory Road, Powell, TN 37849 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$300$300Oct 2, 2007Closed
Citation 1, item 1b
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$0$0Oct 2, 2007Closed
Citation 1, item 1c
29 CFR 1910.134(d)(3)(iiib)(2) · Respiratory protection
Serious$0$0Oct 2, 2007Closed
Citation 1, item 1d
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Oct 2, 2007Closed
Citation 1, item 1e
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Oct 2, 2007Closed
Citation 1, item 1f
29 CFR 1910.134(k)(1)(iv) · Respiratory protection
Serious$0$0Oct 2, 2007Closed
Citation 2, item 1a
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$0$0Oct 2, 2007Closed
Citation 2, item 1b
29 CFR 1910.132(f)(1) · Personal protective equipment, general requirements
Other-than-serious$0$0Oct 2, 2007Closed
Citation 2, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$100$100Oct 2, 2007Closed

Inspection 306128901 OPENED FEB 14, 2003Closed

Planned · Complete · Safety · 20 employees at the site · Closed Apr 2, 2003

1904-b West Emory Road, Powell, TN 37849 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$700$700Mar 6, 2003Closed
Citation 1, item 2a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$400$400Mar 6, 2003Closed
Citation 1, item 2b
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Serious$0$0Mar 6, 2003Closed
Citation 1, item 2c
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$0$0Mar 6, 2003Closed
Citation 1, item 2d
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Mar 6, 2003Closed
Citation 2, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Other-than-serious$0$0Mar 6, 2003Closed

Inspection 303506927 OPENED SEP 13, 2000Closed

Planned · No inspection · Health · Closed Sep 13, 2000

5330 N National Drive, Knoxville, TN 37912 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(e)(1)(i)

(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,

29 CFR 1910.1200(f)(5)(i)

(5) Transportation. (i) Chemical manufacturers, importers, or distributors shall ensure that each container of hazardous chemicals leaving the workplace is labeled, tagged, or marked in accordance with this section in a manner which does not conflict with the requirements of the Hazardous Materials Transportation Act (49 U.S.C. 5101 et seq.) and regulations issued under that Act by the Department of Transportation (49 CFR subtitle B).

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other sheet metal work manufacturing employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.