OSHA SearchOSHA records by employer

Faith First Collision Center, LLC: OSHA inspections and violations

Tucson, Arizona · Automotive Body, Paint, and Interior Repair and Maintenance · NAICS 811121

1inspections
12citation items
$1,200current penalties
Feb 2, 2018last inspection

Faith First Collision Center, LLC has one OSHA inspection on record in Arizona.

OSHA opened it on Feb 2, 2018 after a complaint, in Tucson.

From that inspection OSHA issued 12 citation items: 8 serious and 4 other-than-serious.

OSHA proposed $1,200 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.134, respiratory protection (6 items).

For context, across all repair and personal services employers the median penalty per cited inspection since 2015 is $1,200. Faith First Collision Center, LLC averages $1,200 over 1 cited inspection in that time.

Faith First Collision Center, LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Arizona · latest 90 days of OSHA records

80employers cited

Get notified the morning OSHA posts each new citation in Arizona: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arizona

Checking a subcontractor, a client or your own company? Watch Faith First Collision Center, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342935616 OPENED FEB 2, 2018Closed

Complaint · Partial · Health · 3 employees at the site · Closed Nov 13, 2018

8272 S Camino De Cafe, Tucson, AZ 85747 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$750$750May 9, 2018Final
Citation 1, item 1b
29 CFR 1910.107(c)(7) · Spray painting and finishing
Serious$0$0May 9, 2018Final
Citation 1, item 2a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$450$450May 9, 2018Final
Citation 1, item 2b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0May 9, 2018Final
Citation 1, item 2c
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0May 9, 2018Final
Citation 1, item 2d
29 CFR 1910.134(h)(1) · Respiratory protection
Serious$0$0May 9, 2018Final
Citation 1, item 2e
29 CFR 1910.134(k) · Respiratory protection
Serious$0$0May 9, 2018Final
Citation 1, item 2f
29 CFR 1910.134(l)(1) · Respiratory protection
Serious$0$0May 9, 2018Final
Citation 2, item 1
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0May 9, 2018Final
Citation 2, item 2
29 CFR 1910.1200(f)(6) · Hazard communication
Other-than-serious$0$0May 9, 2018Final
Citation 2, item 3
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0May 9, 2018Final
Citation 2, item 4
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0May 9, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.107(c)(7)

(7) Lamps. Electric lamps outside of, but within twenty (20) feet of any spraying area, and not separated therefrom by a partition, shall be totally enclosed to prevent the falling of hot particles and shall be protected from mechanical injury by suitable guards or by location.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

Other automotive body, paint, and interior repair and maintenance employers in Arizona

Alert subscribers get notified of each newly cited employer in Arizona the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.