Inspection 343049995 OPENED MAR 27, 2018Closed
101 W Jefferson Street 112 W Jefferson Street, Falls Church, VA 22046 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.95(c)(1) · Noise |
Serious | $3,025 | $2,269 | Sep 25, 2018 | Final |
| Citation 1, item 1b 29 CFR 1910.95(d)(1) · Noise |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 1c 29 CFR 1910.95(g)(1) · Noise |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 1d 29 CFR 1910.95(i)(2)(ii)(a) · Noise |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 1e 29 CFR 1910.95(k)(1) · Noise |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 1f 29 CFR 1910.95(l)(1) · Noise |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 1g 29 CFR 1910.95(m)(4) · Noise |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 2a 29 CFR 1910.106(e)(6)(ii) · Flammable liquids |
Serious | $6,235 | $6,235 | Sep 25, 2018 | Final |
| Citation 1, item 2b 29 CFR 1910.106(d)(3)(ii)(a) · Flammable liquids |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 2c 29 CFR 1910.106(e)(2)(iv)(a) · Flammable liquids |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 3a 29 CFR 1910.107(e)(4) · Spray painting and finishing |
Serious | $6,235 | $6,235 | Sep 25, 2018 | Final |
| Citation 1, item 3c 29 CFR 1910.107(b)(5)(i) · Spray painting and finishing |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 4a 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $4,535 | $2,268 | Sep 25, 2018 | Final |
| Citation 1, item 4b 29 CFR 1910.134(c)(2)(ii) · Respiratory protection |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 4c 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 4d 29 CFR 1910.134(f)(2) · Respiratory protection |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 4e 29 CFR 1910.134(k)(5)(i) · Respiratory protection |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 4f 29 CFR 1910.134(k)(6) · Respiratory protection |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 6 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $3,025 | $3,025 | Sep 25, 2018 | Final |
| Citation 1, item 7a 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $2,305 | $2,305 | Sep 25, 2018 | Final |
| Citation 1, item 7b 29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 7c 29 CFR 1910.303(b)(8)(i) · Electrical equipment, general requirements |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 7d 29 CFR 1910.305(a)(2)(ix) · Electrical wiring methods |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 7e 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 7f 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 7g 29 CFR 1910.305(g)(1)(iv)(d) · Electrical wiring methods |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 7h 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 7i 29 CFR 1910.305(j)(1)(i) · Electrical wiring methods |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 7j 29 CFR 1910.307(c) · Hazardous (classified) locations |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 1, item 7k 29 CFR 1910.334(a)(2)(ii) · Using electrical equipment |
Serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 2, item 1 29 CFR 1910.22(b) · Walking-working surfaces |
Other-than-serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 2, item 2 29 CFR 1910.38(b) · Emergency action plans |
Other-than-serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 2, item 3 29 CFR 1910.101(b) · Compressed gases (general requirements) |
Other-than-serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 2, item 4 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 25, 2018 | Final |
| Citation 2, item 5 29 CFR 1910.1200(f)(6)(ii) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 25, 2018 | Final |