Inspection 342183480 OPENED MAR 20, 2017Closed
325 Commerce Drive, Mount Vernon, OH 43050 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Mar 11, 2017: Employee amputates finger when caught in sheet metal roll fo
At 6:50 a.m. on March 11, 2017, an employee was feeding sheet metal into a roll forming machine. The employee was producing three inch diameter HVAC collars on a Niagra roll forming machine. The employee reached up to the top of the machine to retrieve formed collars when his gloved right hand at the index finger was pulled into a pinch point. No adequate guarding was in place. The tip of the employee's index finger was amputated as a result.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements |
Serious | $5,975 | $4,182 | Jun 20, 2017 | Final |
| Citation 1, item 1b 29 CFR 1910.132(d)(1)(i) · Personal protective equipment, general requirements |
Serious | $0 | $0 | Jun 20, 2017 | Final |
| Citation 1, item 1c 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $9,959 | $0 | Jun 20, 2017 | Final |
| Citation 1, item 3 29 CFR 1910.176(b) · Material storage and aisles |
Serious | $9,959 | $6,971 | Jun 20, 2017 | Final |
| Citation 1, item 4 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $9,959 | $6,971 | Jun 20, 2017 | Final |
| Citation 1, item 5 29 CFR 1910.219(i)(2) · Belts, pulleys and power-transmission parts |
Serious | $9,959 | $6,971 | Jun 20, 2017 | Final |
| Citation 2, item 1 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $69,713 | $34,856 | Jun 20, 2017 | Final |
| Citation 3, item 1 29 CFR 1910.1030(g)(2)(i) · Bloodborne pathogens |
Other-than-serious | $0 | $0 | Jun 20, 2017 | Final |