OSHA SearchOSHA records by employer

FBM Siding Perfection, LLC: OSHA inspections and violations

Ridgeley, West Virginia · Siding Contractors · NAICS 238170

1inspections
3citation items
$14,895current penalties
Mar 6, 2025last inspection

OSHA has inspected FBM Siding Perfection, LLC once in West Virginia.

The inspection began on Mar 6, 2025 after a complaint, in Ridgeley; the case is still open.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $14,895 and still stand at $14,895.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and FBM Siding Perfection, LLC averages $14,895 (1 cited inspection).

FBM Siding Perfection, LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

West Virginia · latest 90 days of OSHA records

28employers cited

Get notified the morning OSHA posts each new citation in West Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in West Virginia

Checking a subcontractor, a client or your own company? Watch FBM Siding Perfection, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348087834 OPENED MAR 6, 2025Open

Complaint · Partial · Safety · 2 employees at the site · Open

Across From 114 Meadowland Dr, Ridgeley, WV 26753 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,965$4,965Apr 23, 2025Final
Citation 1, item 2
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$4,965$4,965Apr 23, 2025Final
Citation 1, item 3
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$4,965$4,965Apr 23, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(j)(2)

(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.

Other siding contractors employers in West Virginia

Alert subscribers get notified of each newly cited employer in West Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.