OSHA SearchOSHA records by employer

Fibergrate Composite Structures: OSHA inspections and violations

Stephenville, Texas · All Other Plastics Product Manufacturing · NAICS 326199

3inspections
6citation items
$4,050current penalties
Jun 4, 2015last inspection

OSHA has inspected Fibergrate Composite Structures 3 times in Texas since 2003.

The latest one began on Jun 4, 2015 after a complaint, in Stephenville.

Those inspections ended with 6 citation items: 2 serious and 4 other-than-serious.

Penalties were first proposed at $5,550 and now stand at $4,050, 27% lower after settlements or reviews.

Walking-working surfaces comes up most often in these citations: 2 items under 1910.22.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Fibergrate Composite Structures averages $2,880 (1 cited inspection).

Fibergrate Composite Structures also files yearly injury logs with OSHA, summarized below.

Fibergrate Composite Structures: OSHA citation items per year, 2003 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites Fibergrate Composite Structures again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 340690163 OPENED JUN 4, 2015Closed

Complaint · Partial · Health · 150 employees at the site · Closed Aug 3, 2015

900 Fm 205, Stephenville, TX 76401 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$3,600$2,880Jul 9, 2015Final

Inspection 306204447 OPENED DEC 11, 2003Closed

Planned · Complete · Safety · 168 employees at the site · Closed Feb 5, 2004

900 Fm 205, Stephenville, TX 76401 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$975$585Jan 20, 2004Closed
Citation 1, item 2
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$975$585Jan 20, 2004Closed
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Jan 20, 2004Closed
Citation 2, item 2
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Jan 20, 2004Closed
Citation 2, item 3
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Other-than-serious$0$0Jan 20, 2004Closed

Inspection 305464133 OPENED JAN 30, 2003Closed

Planned · No inspection · Safety · Closed Feb 6, 2003

4285 Kellway Circle, Suite 224, Addison, TX 75001 · Payroll Services · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Stephenville site logged 3 recordable injuries or illnesses among about 117 workers: 2.5 per 100 full-time workers, against a median of 2.6 for its industry. Those cases cost 140 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Fibergrate Composite Structures Incorporated
Stephenville · 2024
117 332.52.6

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.215(b)(9)

(9) Exposure adjustment. Safety guards of the types described in subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b) (3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. (See Figures O-18, O-19, O-20, O-21, O-22, and O-23.)

29 CFR 1910.22 · General requirements

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.253(b)(4)(iii)

(iii) Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

Other all other plastics product manufacturing employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.