OSHA SearchOSHA records by employer

Fiedeldey Steel Fabricators, Inc.: OSHA inspections and violations

Cincinnati, Ohio · Fabricated Structural Metal Manufacturing · NAICS 332312

3inspections
6citation items
$3,700current penalties
Jun 10, 2021last inspection

Since 2002, OSHA inspectors have visited Fiedeldey Steel Fabricators, Inc. in Ohio 3 times.

The most recent inspection opened on Jun 10, 2021 as a planned inspection, in Cincinnati.

In all, OSHA issued 6 citation items: 3 serious and 3 other-than-serious.

The proposed penalties came to $14,777; today they stand at $3,700, 75% less.

The rule cited most here is 1910.147 (lockout/tagout), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Fiedeldey Steel Fabricators, Inc. averages $3,000 across 1 cited inspection.

Fiedeldey Steel Fabricators, Inc. also files yearly injury logs with OSHA, summarized below.

Fiedeldey Steel Fabricators, Inc.: OSHA citation items per year, 2002 to 2021
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

257employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Fiedeldey Steel Fabricators, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345352306 OPENED JUN 10, 2021Closed

Planned · Partial · Safety · 16 employees at the site · Closed Nov 22, 2021

8487 East Miami River Road, Cincinnati, OH 45247 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$3,316$1,500Sep 28, 2021Final
Citation 1, item 4
29 CFR 1910.212(a)(1) · Machine guarding
Serious$5,461$1,500Sep 28, 2021Final

Inspection 314018490 OPENED DEC 16, 2009Closed

Planned · Partial · Safety · 15 employees at the site · Closed Dec 21, 2009

8487 E. Miami River Rd., Cincinnati, OH 45247 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 305078131 OPENED JAN 16, 2002Closed

Planned · Partial · Safety · 19 employees at the site · Closed Apr 9, 2002

8487 E. Miami River Rd., Cincinnati, OH 45247 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Other-than-serious$1,500$0Jan 31, 2002Closed
Citation 1, item 2
29 CFR 1910.147(d)(3) · Lockout/tagout
Other-than-serious$1,500$0Jan 31, 2002Closed
Citation 1, item 3
29 CFR 1910.147(d)(4)(i) · Lockout/tagout
Other-than-serious$1,500$0Jan 31, 2002Closed
Citation 1, item 5
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,500$700Jan 31, 2002Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Cincinnati site logged 0 recordable injuries or illnesses among about 17 workers: 0.0 per 100 full-time workers, against a median of 3.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Fiedeldey Steel Fabricators, Inc.
Cincinnati · 2025
17 000.03.6

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.147(c)(7)(i)

(7) Training and communication. (i) The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:

29 CFR 1910.147(d)(3)

(3) Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s).

29 CFR 1910.212 · Machine guarding

Other fabricated structural metal manufacturing employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.