OSHA SearchOSHA records by employer

Field Construction, LLC: OSHA inspections and violations

Monroe, Ohio · Framing Contractors · NAICS 238130

5inspections
7citation items
$25,756current penalties
Jun 1, 2016last inspection

Field Construction, LLC has 5 OSHA inspections on record in Ohio, the first in 2010.

OSHA's last visit started on Jun 1, 2016 as a planned inspection, in Cincinnati.

Across those inspections OSHA issued 7 citation items: 5 serious and 2 repeat.

OSHA proposed $36,040 in penalties. After settlements and reviews the total is $25,756, down 29%.

Most often, OSHA cited 1926.501, fall protection in construction (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Field Construction, LLC averages $6,852 over 3 cited inspections in that time.

Field Construction, LLC: OSHA citation items per year, 2010 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites Field Construction, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341514990 OPENED JUN 1, 2016Closed

Planned · Partial · Safety · 4 employees at the site · Closed Sep 25, 2023

9329 Bridgecreek Dr., Cincinnati, OH 45231 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$15,400$15,400Jul 19, 2016Final

Inspection 341120475 OPENED DEC 15, 2015Closed

Planned · Partial · Safety · 6 employees at the site · Closed Sep 29, 2023

846-848 Rt. 28, Milford, OH 45150 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$6,160$3,000Mar 16, 2016Final

Inspection 340652650 OPENED MAY 22, 2015Closed

Planned · Partial · Safety · 10 employees at the site · Closed Sep 29, 2023

503-506 Brownston Rd, Springboro, OH 45066 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,080$2,156Jun 24, 2015Final

Inspection 339659526 OPENED APR 2, 2014Closed

Planned · Partial · Safety · 30 employees at the site · Closed Jul 23, 2015

5265 Natorp Dr., Mason, OH 45040 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$3,500$1,750May 30, 2014Final
Citation 1, item 2
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$4,900$2,450May 30, 2014Final

Inspection 314419854 OPENED APR 13, 2010Closed

Planned · Partial · Safety · 5 employees at the site · Closed Dec 15, 2010

552 Babbling Brooke Dr, Monroe, OH 45050 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$1,500$500Apr 27, 2010Closed
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,500$500Apr 27, 2010Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.453(b)(2)(v)

(v) A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift.

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in Ohio

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.