Fiery Plastering: OSHA inspections and violations

Tyler, Texas · Drywall and Insulation Contractors · NAICS 238310

1inspections
3citation items
$12,725current penalties
Jun 2, 2023last inspection

Fiery Plastering has one OSHA inspection on record in Texas.

OSHA opened it on Jun 2, 2023 as a planned inspection, in Tyler.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $12,725 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,078. Fiery Plastering averages $12,725 over 1 cited inspection in that time.

Fiery Plastering: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Want to know if OSHA cites Fiery Plastering again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346743800 OPENED JUN 2, 2023Closed

Planned · Partial · Safety · 2 employees at the site · Closed Jan 12, 2026

2324 Hidden Creek Trail, Tyler, TX 75703 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$3,349$3,349Jun 6, 2023Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,688$4,688Jun 6, 2023Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$4,688$4,688Jun 6, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

Other drywall and insulation contractors employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.