OSHA SearchOSHA records by employer

Filmwerks, LLC: OSHA inspections and violations

Rocky Point, North Carolina · Other Commercial and Industrial Machinery and Equipment Rental and Leasing · NAICS 532490

1inspections
16citation items
$5,330current penalties
Jul 1, 2019last inspection

OSHA has inspected Filmwerks, LLC once in North Carolina.

The inspection began on Jul 1, 2019 after a complaint, in Rocky Point.

That inspection ended with 16 citation items: 9 serious and 7 other-than-serious.

Penalties were first proposed at $8,200 and now stand at $5,330, 35% lower after settlements or reviews.

Spray painting and finishing comes up most often in these citations: 6 items under 1910.107.

How that compares: the median penalty per cited inspection for real estate and rental employers since 2015 is $1,850, and Filmwerks, LLC averages $5,330 (1 cited inspection).

Filmwerks, LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

231employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Filmwerks, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344225149 OPENED JUL 1, 2019Closed

Complaint · Partial · Health · 35 employees at the site · Closed Feb 27, 2020

589 Carver Drive, Rocky Point, NC 28457 · Other Commercial and Industrial Machinery and Equipment Rental and Leasing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$1,500$975Oct 1, 2019Final
Citation 1, item 1b
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$0$0Oct 1, 2019Final
Citation 1, item 1c
29 CFR 1910.107(c)(5) · Spray painting and finishing
Serious$0$0Oct 1, 2019Final
Citation 1, item 1d
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0Oct 1, 2019Final
Citation 1, item 1e
29 CFR 1910.107(e)(2) · Spray painting and finishing
Serious$0$0Oct 1, 2019Final
Citation 1, item 1f
29 CFR 1910.107(g)(7) · Spray painting and finishing
Serious$0$0Oct 1, 2019Final
Citation 1, item 2a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$2,500$1,625Oct 1, 2019Final
Citation 1, item 2b
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$0$0Oct 1, 2019Final
Citation 1, item 3
29 CFR 1910.243(c)(1) · Guarding of portable powered tools
Serious$4,200$2,730Oct 1, 2019Final
Citation 2, item 1a
29 CFR 1910.36(g)(2) · Exit route design
Other-than-serious$0$0Oct 1, 2019Final
Citation 2, item 1b
29 CFR 1910.37(b)(2) · Exit routes
Other-than-serious$0$0Oct 1, 2019Final
Citation 2, item 2a
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Other-than-serious$0$0Oct 1, 2019Final
Citation 2, item 2b
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Other-than-serious$0$0Oct 1, 2019Final
Citation 2, item 3a
29 CFR 1910.134(d)(3)(iii)(b)(2) · Respiratory protection
Other-than-serious$0$0Oct 1, 2019Final
Citation 2, item 3b
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Oct 1, 2019Final
Citation 2, item 4
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 1, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.107(c)(5)

(5) Combustible residues, areas. Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.212 · Machine guarding

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

Other other commercial and industrial machinery and equipment rental and leasing employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.