OSHA SearchOSHA records by employer

Fine Metals Corporation: OSHA inspections and violations

Hanover, Virginia · Secondary Smelting, Refining, and Alloying of Nonferrous Metal (except Copper and Aluminum) · NAICS 331492

6inspections
18citation items
$3,259current penalties
Oct 9, 2018last inspection

Since 2000, OSHA inspectors have visited Fine Metals Corporation in Virginia 6 times.

The most recent inspection opened on Oct 9, 2018 as a planned inspection, in Ashland.

In all, OSHA issued 18 citation items: 13 serious and 5 other-than-serious.

The proposed penalties came to $4,960; today they stand at $3,259, 34% less.

The rule cited most here is 1910.303 (electrical equipment, general requirements), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Fine Metals Corporation averages $990 across 2 cited inspections.

Fine Metals Corporation also files yearly injury logs with OSHA, summarized below.

Fine Metals Corporation: OSHA citation items per year, 2000 to 2018
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

250employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Fine Metals Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343518080 OPENED OCT 9, 2018Closed

Planned · Complete · Safety · 30 employees at the site · Closed Nov 5, 2018

15117 Washington Hwy, Ashland, VA 23005 · Secondary Smelting, Refining, and Alloying of Nonferrous Metal (except Copper and Aluminum) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(b) · Machine guarding
Serious$1,415$990Oct 19, 2018Final
Citation 1, item 2a
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$1,415$990Oct 19, 2018Final
Citation 1, item 2b
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Serious$0$0Oct 19, 2018Final

Inspection 342337441 OPENED MAY 18, 2017Closed

Planned · Complete · Health · 30 employees at the site · Closed Jun 26, 2017

15117 Washington Hwy, Ashland, VA 23005 · Secondary Smelting, Refining, and Alloying of Nonferrous Metal (except Copper and Aluminum) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(f)(6) · Hazard communication
Other-than-serious$0$0Jun 1, 2017Final

Inspection 314421686 OPENED JUN 2, 2010Closed

Planned · Complete · Safety · 24 employees at the site · Closed Jul 8, 2010

15117 Washington Highway, Hanover, VA 23069 · Secondary Smelting, Refining, and Alloying of Nonferrous Metal (except Copper and Aluminum) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$315$189Jun 10, 2010Closed
Citation 1, item 1b
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Serious$0$0Jun 10, 2010Closed
Citation 1, item 2a
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Serious$315$189Jun 10, 2010Closed
Citation 1, item 2b
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Serious$0$0Jun 10, 2010Closed

Inspection 309547297 OPENED NOV 22, 2005Closed

Planned · Complete · Health · 29 employees at the site · Closed Dec 7, 2005

15117 Washington Highway, Hanover, VA 23069 · Secondary Smelting and Alloying of Aluminum · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 305664500 OPENED FEB 13, 2003Closed

Planned · Complete · Safety · 25 employees at the site · Closed Mar 24, 2003

15117 Washington Highway, Hanover, VA 23069 · Secondary Smelting and Alloying of Aluminum · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$300$180Mar 6, 2003Closed
Citation 1, item 2
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$300$180Mar 6, 2003Closed
Citation 1, item 3a
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$225$135Mar 6, 2003Closed
Citation 1, item 3b
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$0$0Mar 6, 2003Closed
Citation 1, item 4
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$225$135Mar 6, 2003Closed
Citation 1, item 5
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$300$180Mar 6, 2003Closed
Citation 2, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Mar 6, 2003Closed
Citation 2, item 2
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Other-than-serious$150$90Mar 6, 2003Closed

Inspection 303214985 OPENED OCT 27, 2000Closed

Planned · Partial · Safety · 14 employees at the site · Closed Dec 20, 2000

15117 Washington Highway, Hanover, VA 23069 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Other-than-serious$0$0Nov 8, 2000Closed
Citation 1, item 2
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Nov 8, 2000Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2020, the Ashland site logged 0 recordable injuries or illnesses among about 32 workers: 0.0 per 100 full-time workers, against a median of 2.7 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Fine Metals Corporation
Ashland · 2020
32 000.02.7

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(6)

(6) Workplace labeling. Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer shall ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked with either:

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

Other secondary smelting, refining, and alloying of nonferrous metal (except copper and aluminum) employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.