Inspection 348520628 OPENED SEP 18, 2025Closed
1824 Brian Dr, Conover, NC 28613 · Showcase, Partition, Shelving, and Locker Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Conover, North Carolina · Showcase, Partition, Shelving, and Locker Manufacturing · NAICS 337215
Framewright, Inc. has 9 OSHA inspections on record in North Carolina, the first in 1998.
OSHA's last visit started on Sep 18, 2025 as a planned inspection, in Conover.
Across those inspections OSHA issued 28 citation items: 7 serious and 21 other-than-serious.
OSHA proposed $3,050 in penalties. After settlements and reviews the total is $950, down 69%.
Most often, OSHA cited 1910.213, woodworking machinery (3 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Framewright, Inc. averages $400 over 1 cited inspection in that time.
Want to know if OSHA cites Framewright, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company1824 Brian Dr, Conover, NC 28613 · Showcase, Partition, Shelving, and Locker Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1824 Brian Dr., Conover, NC 28613 · Showcase, Partition, Shelving, and Locker Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.95(c)(1) · Noise |
Other-than-serious | $2,100 | $0 | Aug 26, 2015 | Closed |
| Citation 2, item 1 29 CFR 1910.147(c)(6)(ii) · Lockout/tagout |
Other-than-serious | $100 | $100 | Aug 26, 2015 | Closed |
| Citation 2, item 2 29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks |
Other-than-serious | $100 | $100 | Aug 26, 2015 | Closed |
| Citation 2, item 3 29 CFR 1910.1200(f)(6)(ii) · Hazard communication |
Other-than-serious | $100 | $100 | Aug 26, 2015 | Closed |
| Citation 2, item 4 29 CFR 1910.1200(h)(3)(iv) · Hazard communication |
Other-than-serious | $100 | $100 | Aug 26, 2015 | Closed |
1824 Brian Dr., Conover, NC 28613 · Other Millwork (including Flooring) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(f) · Electrical equipment, general requirements |
Serious | $150 | $150 | Mar 31, 2010 | Closed |
| Citation 2, item 1 29 CFR 1910.178(l) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Mar 31, 2010 | Closed |
| Citation 2, item 2 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Mar 31, 2010 | Closed |
1824 Brian Drive, North East, Conover, NC 28613 · Showcase, Partition, Shelving, and Locker Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.304(f)(4) · Grounding and circuit protection |
Serious | $100 | $100 | May 26, 2006 | Closed |
| Citation 2, item 1 29 CFR 1910.22(d)(1) · General requirements |
Other-than-serious | $0 | $0 | May 26, 2006 | Closed |
| Citation 2, item 2 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Other-than-serious | $0 | $0 | May 26, 2006 | Closed |
| Citation 2, item 3 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Other-than-serious | $0 | $0 | May 26, 2006 | Closed |
1467 12th Avenue Ne, Hickory, NC 28601 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Jan 5, 2001 | Closed |
| Citation 1, item 1b 29 CFR 1910.132(f)(4) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Jan 5, 2001 | Closed |
1467 12th Avenue Ne, Hickory, NC 28601 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1467 12th Avenue Ne, Hickory, NC 28601 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(4)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | Oct 20, 2000 | Closed |
| Citation 1, item 2 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Oct 20, 2000 | Closed |
1824 Brian Dr., Conover, NC 28613 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1824 Brian Dr., Conover, NC 28613 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.132(a) · Personal protective equipment, general requirements |
Serious | $100 | $100 | Jul 20, 1998 | Closed |
| Citation 1, item 2a 29 CFR 1910.213(l)(2) · Woodworking machinery |
Serious | $100 | $100 | Jul 20, 1998 | Closed |
| Citation 1, item 2b 29 CFR 1910.213(r)(3) · Woodworking machinery |
Serious | $0 | $0 | Jul 20, 1998 | Closed |
| Citation 1, item 2c 29 CFR 1910.213(r)(4) · Woodworking machinery |
Serious | $0 | $0 | Jul 20, 1998 | Closed |
| Citation 1, item 3 29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Jul 20, 1998 | Closed |
| Citation 2, item 1 29 CFR 1910.30(a)(1) · Other working surfaces |
Other-than-serious | $0 | $0 | Jul 20, 1998 | Closed |
| Citation 2, item 2 29 CFR 1910.108(f)(1) · [Reserved] |
Other-than-serious | $0 | $0 | Jul 20, 1998 | Closed |
| Citation 2, item 3 29 CFR 1910.147(c)(6)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | Jul 20, 1998 | Closed |
| Citation 2, item 4 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Jul 20, 1998 | Closed |
| Citation 2, item 5 29 CFR 1910.157(g)(2) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Jul 20, 1998 | Closed |
| Citation 2, item 6 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Other-than-serious | $100 | $100 | Jul 20, 1998 | Closed |
| Citation 2, item 7 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jul 20, 1998 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1200(f)(5)(i)
(5) Transportation. (i) Chemical manufacturers, importers, or distributors shall ensure that each container of hazardous chemicals leaving the workplace is labeled, tagged, or marked in accordance with this section in a manner which does not conflict with the requirements of the Hazardous Materials Transportation Act (49 U.S.C. 5101 et seq.) and regulations issued under that Act by the Department of Transportation (49 CFR subtitle B).
29 CFR 1910.1200(f)(6)(ii)
(ii) Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.
29 CFR 1910.1200(h)(3)(iv)
(iv) The details of the hazard communication program developed by the employer, including an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employees can obtain and use the appropriate hazard information.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.