Francisco Sanchez: OSHA inspections and violations

Converse, Texas · Drywall and Insulation Contractors · NAICS 238310

3inspections
6citation items
$19,832current penalties
Jun 26, 2024last inspection

Since 2018, OSHA inspectors have visited Francisco Sanchez in Texas 3 times.

The most recent inspection opened on Jun 26, 2024 as a planned inspection, in Mckinney and is still open.

In all, OSHA issued 6 citation items: 6 serious.

The penalties, $19,832 in total, stand where OSHA first set them.

The rule cited most here is 1926.501 (fall protection in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Francisco Sanchez averages $6,611 across 3 cited inspections.

Francisco Sanchez: OSHA citation items per year, 2018 to 2024
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Francisco Sanchez and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347587263 OPENED JUN 26, 2024Open

Planned · Partial · Safety · 7 employees at the site · Open

4112 Hydrangea, Mckinney, TX 75071 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,839$4,839Dec 19, 2024Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$3,457$3,457Dec 19, 2024Final

Inspection 345017594 OPENED NOV 4, 2020Closed

Planned · Partial · Safety · 3 employees at the site · Closed Sep 10, 2024

2712 Hart St., Edinburg, TX 78539 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,926$2,926Mar 11, 2021Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,926$2,926Mar 11, 2021Final

Inspection 343462529 OPENED SEP 13, 2018Closed

Planned · Partial · Safety · 6 employees at the site · Closed Apr 6, 2023

8607 Fm 1976 Bldg. 2, Converse, TX 78109 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(1) · Electrical equipment on job sites
Serious$2,842$2,842Jan 23, 2019Final
Citation 1, item 2
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$2,842$2,842Jan 23, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(1)

(b) Examination, installation, and use of equipment—(1) Examination. The employer shall ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined on the basis of the following considerations:

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction