OSHA SearchOSHA records by employer

Frank Miller Lumber Company: OSHA inspections and violations

Union City, Indiana · Sawmills · NAICS 321113

12inspections
102citation items
$17,694current penalties
Dec 7, 2018last inspection

Since 1983, OSHA inspectors have visited Frank Miller Lumber Company in Indiana 12 times.

The most recent inspection opened on Dec 7, 2018 after a complaint, in Union City.

In all, OSHA issued 102 citation items: 64 serious, 4 repeat and 34 other-than-serious.

The proposed penalties came to $24,965; today they stand at $17,694, 29% less.

The rule cited most here is 1910.265 (sawmills), 13 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Frank Miller Lumber Company averages $2,894 across 2 cited inspections.

Frank Miller Lumber Company also files yearly injury logs with OSHA, summarized below.

Frank Miller Lumber Company: OSHA citation items per year, 1983 to 2018
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

82employers cited

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch Frank Miller Lumber Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343695680 OPENED DEC 7, 2018Closed

Complaint · Partial · Safety · 162 employees at the site · Closed Jan 22, 2019

1690 Frank Miller Rd., Union City, IN 47390 · Lumber, Plywood, Millwork, and Wood Panel Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340873447 OPENED AUG 25, 2015Closed

Referral · Partial · Safety · 29 employees at the site · Closed Feb 26, 2016

7016 East Old State Road 56, Salem, IN 47167 · Sawmills · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$1,375$1,375Feb 5, 2016Final
Citation 1, item 2a
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Serious$1,375$1,375Feb 5, 2016Final
Citation 1, item 2b
29 CFR 1910.147(c)(7)(i)(b) · Lockout/tagout
Serious$0$0Feb 5, 2016Final
Citation 2, item 1
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Feb 5, 2016Final

Inspection 317862928 OPENED FEB 23, 2015Closed

Referral · Partial · Safety · 31 employees at the site · Closed Oct 9, 2015

7016 East Old State Road 56, Salem, IN 47167 · All Other Miscellaneous Wood Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,375$894Aug 12, 2015Closed
Citation 1, item 2
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$1,100$715Aug 12, 2015Closed
Citation 1, item 3
29 CFR 1910.305(g)(1)(iva) · Electrical wiring methods
Serious$1,100$715Aug 12, 2015Closed
Citation 1, item 4
29 CFR 1910.1030(f)(2)(i) · Bloodborne pathogens
Serious$1,100$715Aug 12, 2015Closed
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Aug 12, 2015Closed

Inspection 309033421 OPENED OCT 31, 2005Closed

Planned · Complete · Safety · 177 employees at the site · Closed Jan 9, 2006

1690 Frank Miller Rd, Union City, IN 47340 · Sawmills · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$1,100$1,100Dec 7, 2005Closed
Citation 1, item 2
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$1,375$1,375Dec 7, 2005Closed
Citation 1, item 3
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$825$825Dec 7, 2005Closed
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Dec 7, 2005Closed
Citation 2, item 2
29 CFR 1910.303(e) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 7, 2005Closed
Citation 2, item 3
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 7, 2005Closed
Citation 2, item 4
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Dec 7, 2005Closed

Inspection 302013263 OPENED SEP 20, 2000Closed

Planned · Complete · Safety · 176 employees at the site · Closed Oct 16, 2001

1690 Frank Miller Rd, Union City, IN 47340 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.22(d)(2) · General requirements
Serious$675$335Jan 24, 2001Closed
Citation 1, item 1b
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$0$0Jan 24, 2001Closed
Citation 1, item 1c
29 CFR 1910.24(b) · Fixed industrial stairs
Serious$0$0Jan 24, 2001Closed
Citation 1, item 1e
29 CFR 1910.27(b)(1)(ii) · Fixed ladders
Serious$0$0Jan 24, 2001Closed
Citation 1, item 1f
29 CFR 1910.27(d)(3) · Fixed ladders
Serious$0$0Jan 24, 2001Closed
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,575$790Jan 24, 2001Closed
Citation 1, item 3a
29 CFR 1910.179(n)(4)(i) · Overhead and gantry cranes
Serious$675$335Jan 24, 2001Closed
Citation 1, item 3b
29 CFR 1910.179(e)(4) · Overhead and gantry cranes
Serious$0$0Jan 24, 2001Closed
Citation 1, item 4
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,125$560Jan 24, 2001Closed
Citation 1, item 5a
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$900$450Jan 24, 2001Closed
Citation 1, item 5b
29 CFR 1910.212(a)(5) · Machine guarding
Serious$0$0Jan 24, 2001Closed
Citation 1, item 6a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$900$675Jan 24, 2001Closed
Citation 1, item 6b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Jan 24, 2001Closed
Citation 1, item 6c
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$0$0Jan 24, 2001Closed
Citation 1, item 7a Serious$1,575$1,180Jan 24, 2001Closed
Citation 1, item 7c Serious$0$0Jan 24, 2001Closed
Citation 1, item 7e Serious$0$0Jan 24, 2001Closed
Citation 1, item 7f Serious$0$0Jan 24, 2001Closed
Citation 1, item 7g Serious$0$0Jan 24, 2001Closed
Citation 1, item 7h Serious$0$0Jan 24, 2001Closed
Citation 1, item 7i Serious$0$0Jan 24, 2001Closed
Citation 1, item 7j Serious$0$0Jan 24, 2001Closed
Citation 1, item 7k Serious$0$0Jan 24, 2001Closed
Citation 1, item 7l Serious$0$0Jan 24, 2001Closed
Citation 1, item 7m Serious$0$0Jan 24, 2001Closed
Citation 1, item 7n Serious$0$0Jan 24, 2001Closed
Citation 1, item 7p Serious$0$0Jan 24, 2001Closed
Citation 1, item 7q
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$0$0Jan 24, 2001Closed
Citation 1, item 7r
29 CFR 1910.213(m)(1) · Woodworking machinery
Serious$0$0Jan 24, 2001Closed
Citation 1, item 7s
29 CFR 1910.266(d)(1)(iv) · Logging operations
Serious$0$0Jan 24, 2001Closed
Citation 1, item 8a
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$675$335Jan 24, 2001Closed
Citation 1, item 8b
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$0$0Jan 24, 2001Closed
Citation 1, item 8c
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$0$0Jan 24, 2001Closed
Citation 1, item 8d
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Serious$0$0Jan 24, 2001Closed
Citation 1, item 8e
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$0$0Jan 24, 2001Closed
Citation 1, item 8f
29 CFR 1910.307(b)(3) · Hazardous (classified) locations
Serious$0$0Jan 24, 2001Closed
Citation 2, item 1
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Other-than-serious$0$0Jan 24, 2001Closed
Citation 2, item 2
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$0$0Jan 24, 2001Closed
Citation 2, item 3
29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jan 24, 2001Closed
Citation 2, item 4
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Jan 24, 2001Closed
Citation 2, item 5
29 CFR 1910.254(d)(9)(iii) · Arc welding and cutting
Other-than-serious$0$0Jan 24, 2001Closed

Inspection 125377515 OPENED NOV 20, 1995Closed

Planned · No inspection · Safety · 100 employees at the site · Closed Nov 29, 1995

Rt 4 Box 8, Jackson Pike, Union City, IN 47390 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 124058389 OPENED OCT 18, 1993Closed

Planned · Complete · Safety · 80 employees at the site · Closed Jan 5, 1994

Rt 4 Box 8, Jackson Pike, Union City, IN 47390 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Other-than-serious$525$0Nov 10, 1993Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$525$260Nov 10, 1993Closed
Citation 1, item 3a
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$525$260Nov 10, 1993Closed
Citation 1, item 3b
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Serious$0$0Nov 10, 1993Closed
Citation 1, item 4a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$700$525Nov 10, 1993Closed
Citation 1, item 4b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Nov 10, 1993Closed
Citation 1, item 4c
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Nov 10, 1993Closed
Citation 1, item 5
29 CFR 1910.242(b) · Hand and power tools
Serious$525$260Nov 10, 1993Closed
Citation 1, item 6
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$700$350Nov 10, 1993Closed
Citation 2, item 1
29 CFR 4000402
Other-than-serious$350$0Nov 10, 1993Closed
Citation 2, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0Nov 10, 1993Closed
Citation 2, item 3
29 CFR 1910.23(d)(1)(ii) · Guarding floor and wall openings and holes
Other-than-serious$0$0Nov 10, 1993Closed
Citation 2, item 4
29 CFR 1910.38(a)(1) · Emergency action plans
Other-than-serious$0$0Nov 10, 1993Closed
Citation 2, item 5
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0Nov 10, 1993Closed

Inspection 104020631 OPENED OCT 17, 1988Closed

Follow-up · Partial · Safety · 58 employees at the site · Closed Nov 1, 1988

Rt 4 Box 8, Jackson Pike, Union City, IN 47390 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

4 older inspections

Inspection 103976551 OPENED APR 21, 1988Closed

Planned · Complete · Safety · 58 employees at the site · Closed Nov 1, 1988

Rt 4 Box 8, Jackson Pike, Union City, IN 47390 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$210$210Jul 21, 1988Closed
Citation 1, item 1b
29 CFR 1910.304(f)(5) · Grounding and circuit protection
Serious$0$0Jul 21, 1988Closed
Citation 2, item 1
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Repeat$420$420Jul 21, 1988Closed
Citation 2, item 2
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Repeat$420$420Jul 21, 1988Closed
Citation 2, item 3
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Repeat$140$140Jul 21, 1988Closed
Citation 2, item 4
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Repeat$140$140Jul 21, 1988Closed
Citation 3, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Jul 21, 1988Closed
Citation 3, item 2
29 CFR 1910.36(b)(4) · Exit route design
Other-than-serious$0$0Jul 21, 1988Closed
Citation 3, item 3
29 CFR 1910.37(k)(2) · Exit routes
Other-than-serious$0$0Jul 21, 1988Closed
Citation 3, item 4
29 CFR 1910.37(g)(1) · Exit routes
Other-than-serious$0$0Jul 21, 1988Closed
Citation 3, item 5
29 CFR 1910.110(f)(2)(i) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Jul 21, 1988Closed
Citation 3, item 6
29 CFR 1910.110(f)(2)(ii) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Jul 21, 1988Closed
Citation 3, item 7
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Jul 21, 1988Closed
Citation 3, item 8
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$0$0Jul 21, 1988Closed
Citation 3, item 9
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jul 21, 1988Closed
Citation 3, item 10
29 CFR 1910.1200(f)(4)(ii) · Hazard communication
Other-than-serious$0$0Jul 21, 1988Closed
Citation 3, item 11
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Jul 21, 1988Closed
Citation 3, item 12
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Jul 21, 1988Closed

Inspection 101965275 OPENED AUG 5, 1986Closed

Follow-up · Partial · Safety · 33 employees at the site · Closed Aug 12, 1986

Jackson Pike, Union City, IN 47390 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 101965150 OPENED MAY 5, 1986Closed

Planned · Complete · Safety · 33 employees at the site · Closed Jan 11, 1990

Jackson Pike, Union City, IN 47390 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$180$180May 20, 1986Closed
Citation 1, item 2
29 CFR 1910.213(g)(1) · Woodworking machinery
Serious$180$180May 20, 1986Closed
Citation 1, item 3a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$180$180May 20, 1986Closed
Citation 1, item 3b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0May 20, 1986Closed
Citation 1, item 3c
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0May 20, 1986Closed
Citation 1, item 4
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$180$180May 20, 1986Closed
Citation 1, item 5a
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$240$240May 20, 1986Closed
Citation 1, item 5b
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$0$0May 20, 1986Closed
Citation 2, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0May 20, 1986Closed
Citation 2, item 2
29 CFR 1910.106(f)(6) · Flammable liquids
Other-than-serious$0$0May 20, 1986Closed
Citation 2, item 3
29 CFR 1910.178(e)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0May 20, 1986Closed
Citation 2, item 4
29 CFR 1910.212(a)(5) · Machine guarding
Other-than-serious$0$0May 20, 1986Closed
Citation 2, item 5
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0May 20, 1986Closed

Inspection 215185620 OPENED AUG 3, 1983Closed

Planned · Records only · Safety · 21 employees at the site · Closed Aug 12, 1983

Jackson Pike, Union City, IN 47390 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Union City site logged 15 recordable injuries or illnesses among about 141 workers: 10.8 per 100 full-time workers, against a median of 4.2 for its industry. Those cases cost 41 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Frank Miller Lumber Company
Union City · 2025
141 15410.84.2
Frank Miller Lumber Company (Salem)
Salem · 2019
21 6030.94.2

Included with any plan: 10 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1030 · Bloodborne pathogens

29 CFR 1910.1030(f)(2)(i)

(2) Hepatitis B Vaccination. (i) Hepatitis B vaccination shall be made available after the employee has received the training required in paragraph (g)(2)(vii)(I) and within 10 working days of initial assignment to all employees who have occupational exposure unless the employee has previously received the complete hepatitis B vaccination series, antibody testing has revealed that the employee is immune, or the vaccine is contraindicated for medical reasons.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(f)(6)

(6) Sources of ignition. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be handled, drawn, or dispensed where flammable vapors may reach a source of ignition. Smoking shall be prohibited except in designated localities. “No Smoking” signs shall be conspicuously posted where hazard from flammable liquid vapors is normally present.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.110(f)(2)(i)

(2) General. (i) Containers in storage shall be located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.24 · Fixed industrial stairs

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.254 · Arc welding and cutting

29 CFR 1910.265 · Sawmills

29 CFR 1910.266 · Logging operations

29 CFR 1910.27 · Fixed ladders

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

29 CFR 1910.38 · Emergency action plans

Other sawmills employers in Indiana

Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.