OSHA SearchOSHA records by employer

G&C Construction, Inc.: OSHA inspections and violations

Denver, Colorado · Water and Sewer Line and Related Structures Construction · NAICS 237110

1inspections
4citation items
$6,400current penalties
Oct 5, 2015last inspection

OSHA has inspected G&C Construction, Inc. once in Colorado.

The inspection began on Oct 5, 2015 after a complaint, in Denver.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $6,400 and still stand at $6,400.

Excavations comes up most often in these citations: 3 items under 1926.651.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and G&C Construction, Inc. averages $6,400 (1 cited inspection).

G&C Construction, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

136employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch G&C Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340964402 OPENED OCT 5, 2015Closed

Complaint · Partial · Safety · 2 employees at the site · Closed Dec 9, 2015

8500 E Mississippi Ave, Bldg 9, Denver, CO 80247 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$1,600$1,600Oct 26, 2015Final
Citation 1, item 2
29 CFR 1926.651(j)(2) · Excavations
Serious$2,000$2,000Oct 26, 2015Final
Citation 1, item 3a
29 CFR 1926.652(a)(1) · Trench protection
Serious$2,800$2,800Oct 26, 2015Final
Citation 1, item 3b
29 CFR 1926.651(k)(1) · Excavations
Serious$0$0Oct 26, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.