G & C Mold Corporation: OSHA inspections and violations

El Paso, Texas · Machine Shops · NAICS 332710

1inspections
3citation items
$13,395current penalties
May 9, 2023last inspection

G & C Mold Corporation has one OSHA inspection on record in Texas.

OSHA opened it on May 9, 2023 as a planned inspection, in El Paso.

From that inspection OSHA issued 3 citation items: 3 other-than-serious.

OSHA proposed $13,395 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.305, electrical wiring methods (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. G & C Mold Corporation averages $13,395 over 1 cited inspection in that time.

G & C Mold Corporation: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch G & C Mold Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346687536 OPENED MAY 9, 2023Closed

Planned · Partial · Safety · 12 employees at the site · Closed Sep 22, 2023

11430 Cedar Oak Drive, El Paso, TX 79936 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(1)(i) · Electrical wiring methods
Other-than-serious$5,358$5,358Aug 23, 2023Final
Citation 1, item 2
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$3,572$3,572Aug 23, 2023Final
Citation 1, item 3
29 CFR 1910.305(j)(2)(iv) · Electrical wiring methods
Other-than-serious$4,465$4,465Aug 23, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(1)(i)

(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. (i) Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed.

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1910.305(j)(2)(iv)

(iv) A receptacle installed in a wet or damp location shall be suitable for the location.