Inspection 341721025 OPENED AUG 24, 2016Closed
322 Amazon Ave., Cincinnati, OH 45220 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Cincinnati, Ohio · Roofing Contractors · NAICS 238160
Since 1984, OSHA inspectors have visited G&G Roofing, LLC in Ohio 9 times.
The most recent inspection opened on Aug 24, 2016 as a planned inspection, in Cincinnati.
In all, OSHA issued 21 citation items: 14 serious, 2 repeat and 5 other-than-serious.
The proposed penalties came to $28,581; today they stand at $16,891, 41% less.
The rule cited most here is 1926.501 (fall protection in construction), 5 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. G&G Roofing, LLC averages $8,231 across 1 cited inspection.
Ohio · latest 90 days of OSHA records
260employers cited
65 of them in the same industry
Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Ohio
Checking a subcontractor, a client or your own company? Watch G&G Roofing, LLC and get notified the morning OSHA posts a new citation for it.
Watch this company322 Amazon Ave., Cincinnati, OH 45220 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
6810 Cambridge Grove Ct., Cleves, OH 45002 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(13) · Fall protection in construction |
Repeat | $8,231 | $8,231 | Sep 26, 2016 | Final |
5605 Wynnburne Dr., Cincinnati, OH 45238 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(13) · Fall protection in construction |
Serious | $2,800 | $1,960 | Aug 20, 2014 | Final |
3770 Durango Green, Cleves, OH 45002 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(13) · Fall protection in construction |
Serious | $1,050 | $1,050 | Dec 1, 2008 | Closed |
1125 Congress Street, Glendale, OH 45246 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.20(b)(2) · Construction safety programs |
Serious | $2,000 | $1,000 | May 21, 2003 | Closed |
| Citation 1, item 2 29 CFR 1926.503(a)(1) · Fall protection training in construction |
Serious | $2,000 | $1,000 | May 21, 2003 | Closed |
| Citation 1, item 3 29 CFR 1926.1053(b)(13) · Ladders in construction |
Serious | $1,400 | $700 | May 21, 2003 | Closed |
| Citation 1, item 4 29 CFR 1926.1060(b) · Ladder and stairway training |
Serious | $1,400 | $0 | May 21, 2003 | Closed |
| Citation 2, item 1 29 CFR 1926.501(b)(13) · Fall protection in construction |
Repeat | $4,000 | $1,075 | May 21, 2003 | Closed |
3767 Beacon Woods, Cincinnati, OH 45248 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(13) · Fall protection in construction |
Serious | $1,500 | $600 | Nov 25, 2002 | Closed |
| Citation 1, item 2 29 CFR 1926.1053(b)(6) · Ladders in construction |
Serious | $1,500 | $600 | Nov 25, 2002 | Closed |
Bethel Commons Project Site, Columbus, OH 43235 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.104(d) · Safety belts, lifelines, and lanyards |
Other-than-serious | $0 | $0 | Oct 27, 1993 | Closed |
| Citation 1, item 2 29 CFR 1926.104(f) · Safety belts, lifelines, and lanyards |
Other-than-serious | $0 | $0 | Oct 27, 1993 | Closed |
5279 Woodbridge Avenue, Powell, OH 43065 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 4 29 CFR 1926.152(e)(3) · Flammable liquids |
Serious | $450 | $225 | Apr 21, 1993 | Closed |
| Citation 1, item 5 29 CFR 1926.451(a)(13) · Scaffolds, general requirements |
Serious | $450 | $225 | Apr 21, 1993 | Closed |
| Citation 1, item 7a 29 CFR 1926.20(b)(1) · Construction safety programs |
Serious | $450 | $225 | May 20, 1993 | Closed |
| Citation 1, item 7b 29 CFR 1926.20(b)(2) · Construction safety programs |
Serious | $450 | $0 | May 20, 1993 | Closed |
| Citation 1, item 7c 29 CFR 1926.21(b)(2) · Construction safety training |
Serious | $450 | $0 | May 20, 1993 | Closed |
| Citation 1, item 7d 29 CFR 1926.1060(a) · Ladder and stairway training |
Serious | $450 | $0 | May 20, 1993 | Closed |
| Citation 2, item 1 29 CFR 1926.59(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Apr 21, 1993 | Closed |
| Citation 2, item 2 29 CFR 1926.59(h) · Hazard communication |
Other-than-serious | $0 | $0 | Apr 21, 1993 | Closed |
4301 Hunt Rd, Cincinnati, OH 45242 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.25(a) · Housekeeping |
Other-than-serious | $0 | $0 | Jan 23, 1985 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.104(d)
(d) Safety belt lanyard shall be a minimum of 1/2-inch nylon, or equivalent, with a maximum length to provide for a fall of no greater than 6 feet. The rope shall have a nominal breaking strength of 5,400 pounds.
29 CFR 1926.104(f)
(f) All safety belt and lanyard hardware, except rivets, shall be capable of withstanding a tensile loading of 4,000 pounds without cracking, breaking, or taking a permanent deformation.
29 CFR 1926.1053(b)(13)
(13) The top or top step of a stepladder shall not be used as a step.
Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.