OSHA SearchOSHA records by employer

G & H Masonry, LLC.: OSHA inspections and violations

Culloden, West Virginia · Masonry Contractors · NAICS 238140

1inspections
3citation items
$3,600current penalties
Jun 17, 2015last inspection

OSHA has inspected G & H Masonry, LLC. once in West Virginia.

The inspection began on Jun 17, 2015 as a planned inspection, in Culloden.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $6,000 and now stand at $3,600, 40% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and G & H Masonry, LLC. averages $3,600 (1 cited inspection).

G & H Masonry, LLC.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

West Virginia · latest 90 days of OSHA records

28employers cited

Get notified the morning OSHA posts each new citation in West Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in West Virginia

Checking a subcontractor, a client or your own company? Watch G & H Masonry, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340713296 OPENED JUN 17, 2015Closed

Planned · Partial · Safety · 8 employees at the site · Closed Feb 23, 2017

Cornerstone At James River James River Turnpike, Culloden, WV 25510 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,000$1,200Aug 7, 2015Final
Citation 1, item 2
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$2,000$1,200Aug 7, 2015Final
Citation 1, item 3
29 CFR 1926.451(g)(4)(xv) · Scaffolds, general requirements
Serious$2,000$1,200Aug 7, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(1)(ii)

(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).

29 CFR 1926.451(g)(4)(xv)

(xv) Crossbracing is acceptable in place of a midrail when the crossing point of two braces is between 20 inches (0.5 m) and 30 inches (0.8 m) above the work platform or as a toprail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform. The end points at each upright shall be no more than 48 inches (1.3 m) apart.

Other masonry contractors employers in West Virginia

Alert subscribers get notified of each newly cited employer in West Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.