OSHA SearchOSHA records by employer

G.E. Frisco Company, Inc.: OSHA inspections and violations

Upper Marlboro, Maryland · All Other Miscellaneous Wood Product Manufacturing · NAICS 321999

4inspections
53citation items
$5,665current penalties
Oct 16, 2025last inspection

G.E. Frisco Company, Inc. has 4 OSHA inspections on record in Maryland, the first in 1995.

OSHA's last visit started on Oct 16, 2025 on a referral, in Davidsonville.

Across those inspections OSHA issued 53 citation items: 17 serious and 36 other-than-serious.

OSHA proposed $25,900 in penalties. After settlements and reviews the total is $5,665, down 78%.

Most often, OSHA cited 1910.213, woodworking machinery (10 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. G.E. Frisco Company, Inc. averages $5,065 over 1 cited inspection in that time.

G.E. Frisco Company, Inc.: OSHA citation items per year, 1995 to 2025
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

183employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch G.E. Frisco Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348555871 OPENED OCT 16, 2025Closed

Referral · No inspection · Health · Closed Jan 26, 2026

1341 West Central Avenue, Davidsonville, MD 21035 · All Other Miscellaneous Wood Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 348285297 OPENED JUN 3, 2025Closed

Planned · Complete · Safety · 6 employees at the site · Closed Oct 31, 2025

1341 West Central Avenue, Davidsonville, MD 21035 · All Other Miscellaneous Wood Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$1,200$755Oct 15, 2025Final
Citation 1, item 1b
29 CFR 1910.147(c)(5)(i) · Lockout/tagout
Serious$0$0Oct 15, 2025Final
Citation 1, item 1c
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Oct 15, 2025Final
Citation 1, item 1d
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Oct 15, 2025Final
Citation 1, item 2
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$1,000$540Oct 15, 2025Final
Citation 1, item 3a
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$1,200$755Oct 15, 2025Final
Citation 1, item 3b
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$0$0Oct 15, 2025Final
Citation 1, item 3c
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Oct 15, 2025Final
Citation 1, item 4a
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$1,200$755Oct 15, 2025Final
Citation 1, item 4b
29 CFR 1910.213(h)(4) · Woodworking machinery
Serious$0$0Oct 15, 2025Final
Citation 1, item 5
29 CFR 1910.213(i)(1) · Woodworking machinery
Serious$1,200$645Oct 15, 2025Final
Citation 1, item 6a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$1,200$755Oct 15, 2025Final
Citation 1, item 6b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Oct 15, 2025Final
Citation 1, item 6c
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Oct 15, 2025Final
Citation 1, item 6d
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$0$0Oct 15, 2025Final
Citation 1, item 7
29 CFR 1910.242(b) · Hand and power tools
Serious$800$430Oct 15, 2025Final
Citation 1, item 8
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$800$430Oct 15, 2025Final
Citation 2, item 1
29 CFR 1910.29(e)(2) · Fall protection systems in general industry
Other-than-serious$0$0Oct 15, 2025Final
Citation 2, item 2
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Other-than-serious$0$0Oct 15, 2025Final
Citation 2, item 3
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Other-than-serious$0$0Oct 15, 2025Final
Citation 2, item 4
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Oct 15, 2025Final
Citation 2, item 5
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Oct 15, 2025Final
Citation 2, item 6
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Oct 15, 2025Final
Citation 2, item 7
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 15, 2025Final
Citation 2, item 8
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 15, 2025Final
Citation 2, item 9
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 15, 2025Final
Citation 2, item 10
29 CFR 1910.305(b)(1)(i) · Electrical wiring methods
Other-than-serious$0$0Oct 15, 2025Final
Citation 2, item 11
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Oct 15, 2025Final
Citation 2, item 12
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Oct 15, 2025Final

Inspection 300686904 OPENED AUG 5, 1997Closed

Planned · Complete · Safety · 20 employees at the site · Closed Aug 5, 1997

2 S.e. Crain Highway, Upper Marlboro, MD 20772 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 119525095 OPENED MAR 14, 1995Closed

Planned · Complete · Safety · 20 employees at the site · Closed Oct 31, 1995

#2 S. E. Crain Highway, Upper Marlboro, MD 20772 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Other-than-serious$750$100May 31, 1995Final
Citation 2, item 1
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Other-than-serious$1,050$125May 31, 1995Final
Citation 2, item 2
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$1,050$125May 31, 1995Final
Citation 3, item 1
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$1,050$62May 31, 1995Final
Citation 3, item 2
29 CFR 1910.132(f)(1) · Personal protective equipment, general requirements
Other-than-serious$1,050$62May 31, 1995Final
Citation 4, item 1
29 CFR 1910.213(h)(1) · Woodworking machinery
Other-than-serious$1,050$0May 31, 1995Final
Citation 5, item 1a
29 CFR 1910.213(h)(3) · Woodworking machinery
Other-than-serious$1,050$0May 31, 1995Final
Citation 5, item 1b
29 CFR 1910.213(h)(4) · Woodworking machinery
Other-than-serious$0$0May 31, 1995Final
Citation 6, item 1
29 CFR 1910.213(i)(1) · Woodworking machinery
Other-than-serious$1,050$0May 31, 1995Final
Citation 7, item 1a
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Other-than-serious$900$0May 31, 1995Final
Citation 7, item 1b
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0May 31, 1995Final
Citation 7, item 1c
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0May 31, 1995Final
Citation 8, item 1
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$1,050$0May 31, 1995Final
Citation 9, item 1
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$1,050$0May 31, 1995Final
Citation 10, item 1
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Other-than-serious$1,050$0May 31, 1995Final
Citation 10, item 2
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Other-than-serious$1,050$0May 31, 1995Final
Citation 10, item 3
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$1,050$0May 31, 1995Final
Citation 11, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$450$62May 31, 1995Final
Citation 11, item 2
29 CFR 1910.132(f)(4) · Personal protective equipment, general requirements
Other-than-serious$450$62May 31, 1995Final
Citation 11, item 3
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$450$0May 31, 1995Final
Citation 11, item 4
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$450$0May 31, 1995Final
Citation 11, item 5
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$450$0May 31, 1995Final
Citation 11, item 6
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$450$0May 31, 1995Final
Citation 11, item 7 Other-than-serious$350$0May 31, 1995Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 0912.2102

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(i)

(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(a)

(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.

29 CFR 1910.132(d)(1)

(d) Hazard assessment and equipment selection. (1) The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall:

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.29 · Fall protection systems in general industry

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

Other all other miscellaneous wood product manufacturing employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.