OSHA SearchOSHA records by employer

Galvion Ballistics Ltd.: OSHA inspections and violations

Newport, Vermont · Surgical Appliance and Supplies Manufacturing · NAICS 339113

4inspections
10citation items
$77,972current penalties
Apr 21, 2026last inspection

OSHA has inspected Galvion Ballistics Ltd. 4 times in Vermont since 2023.

The latest one began on Apr 21, 2026 after a complaint, in Newport; the case is still open.

Those inspections ended with 10 citation items: 7 serious, 2 repeat and 1 other-than-serious.

Penalties were first proposed at $98,896 and now stand at $77,972, 21% lower after settlements or reviews.

Spray painting and finishing comes up most often in these citations: 7 items under 1910.107.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Galvion Ballistics Ltd. averages $38,986 (2 cited inspections).

Galvion Ballistics Ltd. also files yearly injury logs with OSHA, summarized below.

Galvion Ballistics Ltd.: OSHA citation items per year, 2023 to 2026
Citation items per year, by inspection date.

Vermont · latest 90 days of OSHA records

25employers cited

Get notified the morning OSHA posts each new citation in Vermont: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Vermont

Checking a subcontractor, a client or your own company? Watch Galvion Ballistics Ltd. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348898206 OPENED APR 21, 2026Open

Complaint · Partial · Health · 146 employees at the site · Open

30 Industrial Drive Suite 100, Newport, VT 05855 · Surgical Appliance and Supplies Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 348062944 OPENED FEB 25, 2025Closed

Complaint · Partial · Health · 220 employees at the site · Closed Mar 12, 2025

30 Industrial Drive Suite 100, Newport, VT 05855 · Surgical Appliance and Supplies Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347865321 OPENED NOV 6, 2024Closed

Complaint · Partial · Health · 220 employees at the site · Closed Nov 18, 2025

30 Industrial Drive Suite 100, Newport, VT 05855 · Surgical Appliance and Supplies Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$11,524$6,914Apr 9, 2025Final
Citation 1, item 2
29 CFR 1910.107(e)(4) · Spray painting and finishing
Serious$6,913$4,148Apr 9, 2025Final
Citation 2, item 2
29 CFR 1910.107(d)(12) · Spray painting and finishing
Repeat$34,565$34,565Apr 9, 2025Final
Citation 3, item 1
29 CFR 1910.107(c)(6) · Spray painting and finishing
Repeat$12,025$12,025Apr 9, 2025Final
Citation 4, item 2
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Other-than-serious$1,423$854Apr 9, 2025Final

Inspection 347131724 OPENED NOV 20, 2023Closed

Complaint · Partial · Health · 358 employees at the site · Closed Mar 15, 2024

30 Industrial Drive, Newport, VT 05855 · Surgical Appliance and Supplies Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(d)(1)(i) · Personal protective equipment, general requirements
Serious$10,246$6,147Feb 1, 2024Final
Citation 1, item 2
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$8,539$5,123Feb 1, 2024Final
Citation 1, item 3a
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$8,539$5,123Feb 1, 2024Final
Citation 1, item 3b
29 CFR 1910.107(d)(12) · Spray painting and finishing
Serious$0$0Feb 1, 2024Final
Citation 1, item 4
29 CFR 1910.107(e)(2) · Spray painting and finishing
Serious$5,122$3,073Feb 1, 2024Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Newport site logged 6 recordable injuries or illnesses among about 220 workers: 2.5 per 100 full-time workers, against a median of 1.1 for its industry. Those cases cost 238 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Galvion
Newport · 2024
220 642.51.1

Included with any plan: 3 more yearly logs from these sites, back to 2021, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.107(d)(12)

(12) Drying spaces. Freshly sprayed articles shall be dried only in spaces provided with adequate ventilation to prevent the formation of explosive vapors. In the event adequate and reliable ventilation is not provided such drying spaces shall be considered a spraying area. See also paragraph (j) of this section.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

Other surgical appliance and supplies manufacturing employers in Vermont

Alert subscribers get notified of each newly cited employer in Vermont the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.