OSHA SearchOSHA records by employer

Gann Electric Inc: OSHA inspections and violations

Franklin, Indiana · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
7citation items
$4,192current penalties
Dec 12, 2018last inspection

OSHA inspectors have visited Gann Electric Inc in Indiana one time.

It opened on Dec 12, 2018, in Franklin.

In all, OSHA issued 7 citation items: 7 serious.

The proposed penalties came to $9,450; today they stand at $4,192, 56% less.

The rule cited most here is 1926.416 (electrical safety in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Gann Electric Inc averages $4,192 across 1 cited inspection.

Gann Electric Inc: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

84employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch Gann Electric Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343669511 OPENED DEC 12, 2018Closed

Unprogrammed other · Complete · Safety · 4 employees at the site · Closed Apr 30, 2019

250 Paris Road, Franklin, IN 46131 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$450$292Mar 5, 2019Final
Citation 1, item 2
29 CFR 1926.150(c)(1)(i) · Fire protection
Serious$1,500$975Mar 5, 2019Final
Citation 1, item 3
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$1,500$975Mar 5, 2019Final
Citation 1, item 4
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Serious$1,500$975Mar 5, 2019Final
Citation 1, item 5
29 CFR 1926.405(j)(1)(i) · Job-site wiring
Serious$1,500$0Mar 5, 2019Final
Citation 1, item 6
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$1,500$975Mar 5, 2019Final
Citation 1, item 7
29 CFR 1926.416(b)(2) · Electrical safety in construction
Serious$1,500$0Mar 5, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(i)(2)(i)

(2) Guarding of live parts. (i) Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means:

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

Other electrical contractors and other wiring installation contractors employers in Indiana

Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.