OSHA SearchOSHA records by employer

Gartek, Inc.: OSHA inspections and violations

Berwick, Pennsylvania · Electroplating, Plating, Polishing, Anodizing, and Coloring · NAICS 332813

1inspections
2citation items
$1,320current penalties
Jan 25, 2018last inspection

OSHA inspectors have visited Gartek, Inc. in Pennsylvania one time.

It opened on Jan 25, 2018 after a complaint, in Berwick.

In all, OSHA issued 2 citation items: 2 serious.

The proposed penalties came to $1,885; today they stand at $1,320, 30% less.

The rule cited most here is 1910.107 (spray painting and finishing), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Gartek, Inc. averages $1,320 across 1 cited inspection.

Gartek, Inc.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

295employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Gartek, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342899259 OPENED JAN 25, 2018Closed

Complaint · Partial · Health · 14 employees at the site · Closed May 31, 2018

2100 Dickson Street, Berwick, PA 18603 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(3) · Spray painting and finishing
Serious$1,885$1,320Mar 26, 2018Final
Citation 1, item 1b
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$0$0Mar 26, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(3)

(3) Floors. The floor surface of a spray booth and operator's working area, if combustible, shall be covered with noncombustible material of such character as to facilitate the safe cleaning and removal of residues.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

Other electroplating, plating, polishing, anodizing, and coloring employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.