OSHA SearchOSHA records by employer

Gci Construction, LLC: OSHA inspections and violations

Cary, North Carolina · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

3inspections
8citation items
$2,200current penalties
Aug 9, 2017last inspection

Since 2008, OSHA inspectors have visited Gci Construction, LLC in North Carolina 3 times.

The most recent inspection opened on Aug 9, 2017 as a planned inspection, in Wake Forest.

In all, OSHA issued 8 citation items: 8 serious.

The proposed penalties came to $4,800; today they stand at $2,200, 54% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Gci Construction, LLC averages $1,000 across 1 cited inspection.

Gci Construction, LLC: OSHA citation items per year, 2008 to 2017
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

237employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Gci Construction, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342534278 OPENED AUG 9, 2017Closed

Planned · Complete · Safety · 3 employees at the site · Closed Nov 13, 2017

1200 Debarmore Street, Wake Forest, NC 27587 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(3) · Construction safety programs
Serious$1,000$1,000Sep 12, 2017Final
Citation 1, item 1c
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$0$0Sep 12, 2017Final

Inspection 341217552 OPENED JAN 27, 2016Closed

Unprogrammed related · Partial · Safety · 2 employees at the site · Closed Feb 8, 2016

5215 Noble Dr. Nw (building #15), Concord, NC 28027 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311937015 OPENED JUN 19, 2008Closed

Planned · Complete · Safety · 2 employees at the site · Closed Aug 28, 2008

1021 Royal Burkdale Drive, Cary, NC 27511 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$500$500Jul 8, 2008Closed
Citation 1, item 3
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$700$0Jul 8, 2008Closed
Citation 1, item 4
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$700$0Jul 8, 2008Closed
Citation 1, item 5
29 CFR 1926.451(g)(4)(iv) · Scaffolds, general requirements
Serious$700$0Jul 8, 2008Closed
Citation 1, item 6
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$700$700Jul 8, 2008Closed
Citation 1, item 7
29 CFR 1926.602(c)(1)(viiia) · Earthmovers and forklifts in construction
Serious$500$0Jul 8, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(3)

(3) The use of any machinery, tool, material, or equipment which is not in compliance with any applicable requirement of this part is prohibited. Such machine, tool, material, or equipment shall either be identified as unsafe by tagging or locking the controls to render them inoperable or shall be physically removed from its place of operation.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(c)(3)

(3) Supported scaffold poles, legs, posts, frames, and uprights shall be plumb and braced to prevent swaying and displacement.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.602 · Earthmovers and forklifts in construction

29 CFR 9501.2901

Other new multifamily housing construction (except for-sale builders) employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.