GCL, Inc.: OSHA inspections and violations

Butler, Pennsylvania · Fabricated Structural Metal Manufacturing · NAICS 332312

11inspections
33citation items
$8,892current penalties
Jun 11, 2024last inspection

Since 2001, OSHA inspectors have visited GCL, Inc. in Pennsylvania 11 times.

The most recent inspection opened on Jun 11, 2024 as a planned inspection, in Butler.

In all, OSHA issued 33 citation items: 27 serious and 6 other-than-serious.

The proposed penalties came to $13,800; today they stand at $8,892, 36% less.

The rule cited most here is 1910.217 (mechanical power presses), 8 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. GCL, Inc. averages $2,835 across 2 cited inspections.

GCL, Inc. also files yearly injury logs with OSHA, summarized below.

GCL, Inc.: OSHA citation items per year, 2001 to 2024
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

295employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch GCL, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347540460 OPENED JUN 11, 2024Closed

Planned · No inspection · Health · Closed Jun 12, 2024

685 Glenwood Way, Butler, PA 16001 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341340545 OPENED MAR 22, 2016Closed

Referral · Partial · Health · 20 employees at the site · Closed Jul 11, 2016

205 Kittanning Street, Butler, PA 16001 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$2,000$1,200May 20, 2016Final
Citation 1, item 1b
29 CFR 1910.106(d)(4)(iii) · Flammable liquids
Serious$0$0May 20, 2016Final
Citation 1, item 1c
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$0$0May 20, 2016Final
Citation 1, item 2a
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$2,000$1,200May 20, 2016Final
Citation 1, item 3a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$1,200$720May 20, 2016Final
Citation 1, item 3b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0May 20, 2016Final
Citation 1, item 3c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0May 20, 2016Final
Citation 1, item 3d
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Serious$0$0May 20, 2016Final
Citation 1, item 3e
29 CFR 1910.134(k)(1)(i) · Respiratory protection
Serious$0$0May 20, 2016Final

Inspection 341268647 OPENED FEB 22, 2016Closed

Planned · Partial · Safety · 20 employees at the site · Closed Jun 14, 2016

685 Glenwood Way, Butler, PA 16001 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3) · Machine guarding
Serious$1,700$1,275Apr 21, 2016Final
Citation 1, item 2
29 CFR 1910.217(c)(2)(i)(a) · Mechanical power presses
Serious$1,700$1,275Apr 21, 2016Final
Citation 2, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Other-than-serious$0$0Apr 21, 2016Final
Citation 2, item 2
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Other-than-serious$0$0Apr 21, 2016Final

Inspection 340819457 OPENED JUN 24, 2015Closed

Planned · No inspection · Health · 14 employees at the site · Closed Jun 24, 2015

685 Glenwood Way, Butler, PA 16001 · Forging and Stamping · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312627821 OPENED FEB 17, 2009Closed

Follow-up · Partial · Health · 16 employees at the site · Closed Feb 19, 2009

685 Glenwood Way, Butler, PA 16001 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312627649 OPENED OCT 30, 2008Closed

Follow-up · Partial · Safety · 16 employees at the site · Closed Oct 30, 2008

685 Glenwood Way, Butler, PA 16001 · Metalworking Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311328645 OPENED JUL 18, 2008Closed

Referral · Partial · Safety · 15 employees at the site · Closed May 18, 2009

685 Glenwood Way, Butler, PA 16001 · Metalworking Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$750$375Aug 7, 2008Closed
Citation 1, item 2a
29 CFR 1910.217(b)(4)(i) · Mechanical power presses
Serious$750$375Aug 7, 2008Closed
Citation 1, item 2b
29 CFR 1910.217(c)(2)(ia) · Mechanical power presses
Serious$0$0Aug 7, 2008Closed

Inspection 311328900 OPENED JUN 27, 2008Closed

Planned · Partial · Health · 17 employees at the site · Closed Sep 8, 2009

685 Glenwood Way, Butler, PA 16001 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$525$250Jul 28, 2008Final
Citation 1, item 1b Serious$0$0Jul 28, 2008Final
Citation 1, item 1c Serious$0$0Jul 28, 2008Final
Citation 1, item 1d Serious$0$0Jul 28, 2008Final
3 older inspections

Inspection 306769308 OPENED MAY 13, 2004Closed

Complaint · Partial · Safety · 21 employees at the site · Closed May 19, 2004

685 Glenwood Way, Butler, PA 16001 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306902917 OPENED OCT 8, 2003Closed

Planned · Partial · Safety · 16 employees at the site · Closed Nov 5, 2003

685 Glenwood Way, Butler, PA 16001 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$500$350Oct 17, 2003Closed
Citation 1, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$500$350Oct 17, 2003Closed

Inspection 304180938 OPENED AUG 17, 2001Closed

Complaint · Partial · Safety · 22 employees at the site · Closed Sep 20, 2001

685 Glenwood Way, Butler, PA 16001 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$525$368Aug 23, 2001Closed
Citation 1, item 2
29 CFR 1910.217(d)(6)(i) · Mechanical power presses
Serious$300$210Aug 23, 2001Closed
Citation 1, item 3
29 CFR 1910.217(b)(4)(i) · Mechanical power presses
Serious$300$210Aug 23, 2001Closed
Citation 1, item 4
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Serious$300$210Aug 23, 2001Closed
Citation 1, item 5
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$525$368Aug 23, 2001Closed
Citation 1, item 6a
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$225$157Aug 23, 2001Closed
Citation 1, item 6b
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$0$0Aug 23, 2001Closed
Citation 2, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Other-than-serious$0$0Aug 23, 2001Closed
Citation 2, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Aug 23, 2001Closed
Citation 2, item 3
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Aug 23, 2001Closed
Citation 2, item 4
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Aug 23, 2001Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2017, the Butler site logged 1 recordable injury or illness among about 23 workers: 7.0 per 100 full-time workers, against a median of 3.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
GCL Inc
Butler · 2017
23 107.03.6

Included with any plan: 1 more yearly log from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iii)

(iii) Wiring. Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) and Category 4 flammable liquids, shall be approved for general use.

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.212 · Machine guarding

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.95 · Noise

Other fabricated structural metal manufacturing employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.